To accommodate telephone, data, CATV, security and multimedia, a MINIMUM of ________ strands of optical fiber auxiliary disconnect outlet (ADO) cable should be provided.

To accommodate telephone, data, CATV, security and multimedia, a MINIMUM of ________ strands of optical fiber auxiliary disconnect outlet (ADO) cable should be provided.A . TwoB . FourC . FiveD . SixE . EightView AnswerAnswer: B

August 28, 2022 No Comments READ MORE +

What is the PRIMARY reason for considering a physical ting topology for connecting outlying buildings?

What is the PRIMARY reason for considering a physical ting topology for connecting outlying buildings?A . It is the most cost effective design ten a campus network.B . It provides a redundant cable path for disaster recovery.C . It is the most compelling design for any network requirement.D . It...

August 28, 2022 No Comments READ MORE +

How many classes of telecommunications administration are there?

How many classes of telecommunications administration are there?A . 3B . 4C . 5D . 6View AnswerAnswer: B

August 28, 2022 No Comments READ MORE +

What is to be the MINIMUM size of the TR?

The ICT distribution designer is hired to design a Telecommunications Room on the third floor of a building. The size of the floor is 20 m by 26 m (92 x 85 It). What is to be the MINIMUM size of the TR?A . Shallow Room, no minimum room sizeB...

August 28, 2022 No Comments READ MORE +

When designing horizontal pathways, the ICT distribution designer should consider the design's ability to (Select two options.)

When designing horizontal pathways, the ICT distribution designer should consider the design's ability to (Select two options.)A . handle only the day one needs as the future is unknown.B . minimize occupant disruption when horizontal pathways are accessed.C . handle at least 3 different cabling media types.D . accommodate cabling...

August 27, 2022 No Comments READ MORE +

Identify the core switch(es) and server(s) of the data center in the diagram below by dragging the appropriate term into each box in the diagram

DRAG DROP Identify the core switch(es) and server(s) of the data center in the diagram below by dragging the appropriate term into each box in the diagram. View AnswerAnswer:

August 27, 2022 No Comments READ MORE +

Conducted coupling may affect electronic devices primarily through which two of the following means'? (Select two options.)

Conducted coupling may affect electronic devices primarily through which two of the following means'? (Select two options.)A . inductive coupling (by magnetic fields)B . Input signal linesC . Output signal linesD . Optical signal linesE . Capacitive coupling (by electric fields)View AnswerAnswer: B, C

August 27, 2022 No Comments READ MORE +

In which of the following design phases does the ICT distribution designer perform coordination with stakeholders and other disciplines (e.g.. mechanical, architectural, electrical) to ensure that the design is constructive and that any conflicts are resolved early in the process?

In which of the following design phases does the ICT distribution designer perform coordination with stakeholders and other disciplines (e.g.. mechanical, architectural, electrical) to ensure that the design is constructive and that any conflicts are resolved early in the process?A . Concept DesignB . Design Development (DD)C . Schematic Design...

August 27, 2022 No Comments READ MORE +

An Ethernet passive optical network (EPON) uses an aggregation device called an optical line terminal (OLT). An OLT can support a MINIMUM of______subscribers per port using a passive optical splitter

An Ethernet passive optical network (EPON) uses an aggregation device called an optical line terminal (OLT). An OLT can support a MINIMUM of______subscribers per port using a passive optical splitterA . 8B . 16C . 32D . 64View AnswerAnswer: B

August 27, 2022 No Comments READ MORE +

Which of the following is a consideration for lighting telecommunication spaces?

Which of the following is a consideration for lighting telecommunication spaces?A . To ensure worker safety within TEs. Light level requirements are higher tor these than other spacesB . The light fixtures within telecommunications spaces shall be fluorescent type fixtures.C . The electrical power for lighting shall be connected to...

August 27, 2022 No Comments READ MORE +