Which two steps are required for this migration and cutover?

You plan to use Foreign LUN Import (FLI) to migrate data from an older storage array to an ONTAP cluster. You have properly cabled the storage array and the NetApp nodes to your dual-fabric SAN.

Which two steps are required for this migration and cutover? (Choose two.)
A . Add NetApp WWN initiator ports to the existing zones.
B . Add NetApp WWN target ports to the existing zones so that your hosts can access both storage arrays.
C . Create two zones that contain the NetApp target ports and the host initiators ports, one for each fabric.
D . Create two zones that contain NetApp initiator ports and the source storage target ports, one for each fabric.

Answer: BC

Latest NS0-519 Dumps Valid Version with 60 Q&As

Latest And Valid Q&A | Instant Download | Once Fail, Full Refund

Subscribe
Notify of
guest
1 Comment
Inline Feedbacks
View all comments
pietje puk
pietje puk
2 years ago

(CD)

A standard migration scenario using FLI requires four distinct zones:

Zone 1: Source storage to destination storage (production fabric A)
Zone 2: Source storage to destination storage (production fabric B)
Zone 3: Host to destination storage (production fabric A)
Zone 4: Host to destination storage (production fabric B)

Follow these zoning best practices:
Do not mix source storage target ports and destination storage target ports in the same zone.
Do not mix destination storage initiator ports and host ports in the same zone.
Do not mix destination storage target and initiator ports in the same zone.
Zone with at least two ports from each controller for redundancy.
NetApp recommends single initiator and single target zoning.