What caused this issue?

A Cisco UCS system is operating in FC End-Host Mode. The fabric Interconnects are uplinked into Nexus 5672UP switches using native FC. The service profiles are unable to boot from SAN using FC.

When executing the show flogi database command on the Nexus switches, only the Fabric Interconnect port WWNs are visible. No service profile WWNs are shown.

What caused this issue?
A . The Nexus switches do not have NPV enabled.
B . The Nexus must be configured for FCoE instead of native Fibre Channel.
C . The Nexus switches do not have NPIV enabled.
D . The zoning on the Nexus switches is incorrect.

Answer: C