In this situation, what would be your next step?

You have a customer complaining of long build times from their NetApp ONTAP-based datastores. They provided you packet traces from the controller and client. Analysis of these traces shows an average service response time of 1 ms. QoS outputconfirms the same. The client traces are reporting an average of 15 ms in the same time period.

In this situation, what would be your next step?
A . The cluster is responding slowly and requires further investigation using performance archives.
B. The client that reports high latency should be investigated.
C. The cluster interconnects should be investigated.
D. A sync core should be triggered.

Answer: B

In this scenario, which two NFS SVM parameters should be enabled?

Your customer has deployed a two petabyte NetAppONTAP FlexGroup volume across their 4-node ONIAP 9.8 cluster. They plan to store over three billion files. They want to prevent file 10 conflicts since files are placed into the FlexGroup volume.

In this scenario, which two NFS SVM parameters should be enabled? (Choose two.)
A . -v3-64bit-identifiers
B. -v4-fsid-change
C. -v3-fsid-change
D. -v4-64bit-idantifiers

Answer: A,C

Referring to the exhibit, which statement is correct?

A 2-node cluster hosts only NAS data UFs. Allnodes lose access to the cluster network.

Referring to the exhibit, which statement is correct?
A . Both nodes race to takeover the other, one node will takeover the other node.
B. No takeover event will occur and NAS data UFs will not be accessible.
C. All nodes in the cluster reset and NAS data UFs are not accessible after reboot.
D. NAS data UFs are accessible on only the node that has Epsilon.

Answer: C

What Information would you tell your customer in this scenario?

A customer’s storage administrator Informs you about the deactivated Automatic Switchover (AUSO) feature on their MetroCluster IP environment.

What Information would you tell your customer in this scenario?
A . The AUSO feature cannot be activated due to a non-mirrored aggregate.
B. The AUSO feature is not available in Metrocluster IP installations by design.
C. A faulty link automatically deactivated the AUSO feature.
D. This is a configuration failure, you can activate that feature for the customer.

Answer: A

Referring to the exhibit, which statement is correct?

Your customer added a new DS4246 shelf to their FAS2750 single-node system and created a new aggregate on the new shelf. Two weeks later, they log into Active IQ and discover the Medium Impact error shown below.

Shelves with both connections via the same SAS path detected

Referring to the exhibit, which statement is correct?
A . In a FAS2750 system, the internal shelf is only seen on one path, and the external shelves are seen on two paths.
B. The cables are cabled Incorrectly on the SAS stack.
C. This situation is normal for a FA57750 single-node system.
D. Active IQ Is not aware of the shelf configuration for a single-node system.

Answer: C

Referring to the exhibit, which corrective action would address these consistency points?

You have a 2-node NetApp FAS2750 switchless cluster with twenty-four 1.8 TB disks that is experiencing performance issues.

Upon investigation, you discover severaltype B consistency points.

Referring to the exhibit, which corrective action would address these consistency points?
A . Create additional data LIFs.
B. Convert the 2-node switchless cluster to a 2-node switched cluster.
C. Add an additional shelf oftwenty-four 1.8 TB disks.
D. Replace the twenty-four 1.8 TB disks with twelve 4 TB disks.

Answer: C

In this situation, how do you determine whether core dumps are generated for the mgwd user space process?

You receive the "Unable to connect to the management gateway server"error when trying to connect to a node management IP.

In this situation, how do you determine whether core dumps are generated for the mgwd user space process?
A . Log in to the nodeshell using the node console and collect the core dumps from the nodeshell.
B. Log in to the service processor and collect the core dumps from the service processor.
C. Log in to the clustershell using the node console and collect the core dumps from the clustershell.
D. Log in to the systemshell and collect core dumps from thesystemshell.

Answer: B

How would youaccomplish this task?

You are attempting to connect a NetApp ONTAP cluster to a very complex network that requires LIFs to fail over across subnets.

How would youaccomplish this task?
A . Configure an equal number of UFs on each subnet.
B. Configure VIP LIFs using OSPF.
C. Configure VIP LIFs using BGP.
D. Configure a I IF failover policy for each subnet inside a single broadcast domain.

Answer: C

What would cause this error?

You created a new NetApp ONTAP FlexGroup volume spanning six nodes and 12 aggregates with a total size of 4 TB. You added millions of files to the FlexGroup volume with a flat directory structure totaling 2 TB, and you receive anout of apace error message on your host.

What would cause this error?
A . The maximum number of volume constituents has been reached in the ONTAP software.
B. All constituent volumes are full.
C. The inode limit is exceeded in the ONTAP software.
D. The maxdirsize Is exceeded in the ONTAP software.

Answer: C

In this scenario, what Is the cause of this problem?

Your customer complains about missing volume snapshot copies on a SnapMlrror destination. While investigating this case, you notice an executed SnapMirror resync operation in the event logs of the system.

In this scenario, what Is the cause of this problem?
A . Newer Snapshot copies than the common snapshot that was chosen for resync were removed automatically at the destination.
B. The autodelete option removed Snapshot copies before the resync.
C. Snapshot copies were manually removed from the destination after the resync.
D. NetApp ON TAP System Manager removed these snapshot copies due to a snapshot schedule.

Answer: C