Referring to the exhibit, what is the reason for this problem?

Your customer wants to access a LUN on a FAS 8300 system from a VMware ESXi server through the FC protocol. They already created a new SVM, volume. LUN, and igroup for this purpose. The customer reports that the server's FC HBA port Is online, but the LUN does not...

September 16, 2022 No Comments READ MORE +

In this scenario, what are two actions that must be performed?

Your customer mentions that they have accidentally destroyed both rootaggregates in their two-node cluster. In this scenario, what are two actions that must be performed? (Choose two.)A . Rejoin the second node to the re-created cluster. B. Re-create the cluster from the local backup. C. Install ONTAP from a USB...

September 16, 2022 No Comments READ MORE +

Which two automation methods does NetApp ONTAP Select support? (Choose two.)

Which two automation methods does NetApp ONTAP Select support? (Choose two.)A . REST B. Anslble C. Docker D. PHPView AnswerAnswer: A,B

September 15, 2022 No Comments READ MORE +

In this scenario, which component should you troubleshoot first?

You receive the panic message shown in the exhibit. In this scenario, which component should you troubleshoot first?A . the PCI card in slot 3 B. the MetroCluster FC-Vl card in slot 6 C. the memory module in slot 1 D. the CPUView AnswerAnswer: D

September 14, 2022 No Comments READ MORE +

Referring to the exhibit, what do you need to do to return the MetroCluster to a normal state?

Referring to the exhibit, what do you need to do to return the MetroCluster to a normal state? A. Enter the metroclustor switchback command on Site B. B. Enter the metrocluster switchback command on Site A. C. Enter the storage failover giveback command on Site B. D. Enter the storage...

September 14, 2022 No Comments READ MORE +

In this scenario, which statement is true?

You notice poor performance on your FlexGroup and execute the system node run -node * flexgroup show command for more Information. You notice the "Urge" column has non-zero values. In this scenario, which statement is true?A . The aggregate is completely full. B. The constituent volumes are out ofInodes. C....

September 13, 2022 No Comments READ MORE +

In this scenario, what is causing this problem?

After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is accessed indirectly. The system node run -node -command netstat command shows retransmits and packet drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10...

September 13, 2022 No Comments READ MORE +

In this scenario, which VMware feature Is supported by ONTAP software to accomplish this task?

You have a new VMware vSphere cluster with ESXI 7.0U2 hosts. The hosts are connected to a 4-node AFF A400 NetApp ONTAP9.8 cluster with FC LUNs. You have a requirement to identify and follow I/Os from each VM on the shared FC LUN-backed datastores for troubleshooting purposes. In this scenario,...

September 10, 2022 No Comments READ MORE +

What has happened in this situation?

The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02. Node-02 panics showing the string below. PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess fnmbx_instanceWorker on release 9.5P8 (C) What has happened in this situation?A . While in...

September 10, 2022 No Comments READ MORE +

Which FIFO message Is useful for Investigating this Issue?

A system panic due to an "L2 watchdog timeout hard reset" error occurred. You have found a FIFO message in the SP log. Which FIFO message Is useful for Investigating this Issue?A . before NMI BBSP:C=00 L=00 FIFO: F3 F2 F1 F0 5 B2 0 0 0 80 20 E...

September 9, 2022 No Comments READ MORE +