Which of the following descriptions for the configuration of the PDU8000 modular precision power distribution cabinet is correct?
- A . Modular precision power distribution cabinet supports single and dual input
- B . Modular precision power distribution cabinet supports up to 4 output modules
- C . The output module of the modular precision power distribution cabinet only supports 1P air switch
- D . The input modules of the modular precision power distribution cabinet are MCCB and ATS.
If the customer’s load cannot be powered off, what should be paid attention to disconnecting the maintenance bypass switch after the maintenance is completed?
- A . The circuit module is normal and can supply power
- B . The maintenance bypass switch can also be disconnected when the bypass module is abnormal
- C . EPO filling can break the maintenance switch
- D . The battery input is normal
The default battery charging voltage of UPS2000-G is () V/CELL.
- A . 2.25
- B . 2.35
- C . 2.45
- D . 2.15
Which of the following features are standard features of NETCOL8000-C air conditioners?
- A . Dual power supply
- B . Water Immersion Sensor
- C . G4-level filter
- D . Humidification function
Three groups of 9AH battery packs are connected in parallel to UPS2000-G-6KVA, the battery capacity should be set to ().
- A . 9AH
- B . 18AH
- C . 27AH
- D . 32AH
The straight pipe distance of NETCOL5000-C pipeline fixed title is ().
- A . 3200MM
- B . 3000MM
- C . 2600MM
- D . 2500MM
When the outdoor units of Huawei air-cooled air conditioners are installed horizontally, the distance between the two outdoor units is ≥ () MM.
- A . 400
- B . 800
- C . 1200
- D . 2000
When the internal short circuit of the battery occurs, the charging voltage of the faulty battery (), the open circuit voltage is low (generally less than 1V/CELL).
- A . high
- B . unchanged
- C . low
- D . is all possible
In the naming of UPS5000-E-120K-HASBS, the meaning of the letter E is ().
- A . 208V voltage body
- B . E-Series Modular UPS
- C . Input switch type is ATS
- D . Input switch type is MCCB
The () components of Huawei NETCOL5000-A in-line precision air conditioner are optional parts.
- A . Fan
- B . Evaporator
- C . Compressor
- D . Electric heating