Which configuration must the ISP engineer apply?

An ISP Is Implementing end-to-end fault monitoring for a customer based on the IEEE 802.3ah standard. The solution must detect when 15 or more corrupted Ethernet packets arrive within 10 ms and stop propagating traffic through the ISP backbone network or to the customer side.

Which configuration must the ISP engineer apply?
A . ethernet oam link-monitoring enable
ethernet oam link-monitor crc-errors ingress time-window 10
ethernet oam link-monitor crc-errors ingress threshold high 15
ethernet oam link-monitor crc-errors egress time-window 10
ethernet oam link-monitor crc-errors egress threshold high 15
ethernet oam link-monitor high-threshold action shutdown-interface
B. ethernet oam link-monitoring
ethernet oam link-monitor receive-crc window 15
ethernet oam link-monitor receive-crc threshold high 10
ethernet oam link-monitor high-threshold action disable-interface
C. ethernet oam
ethernet oam link-monitor receive-crc window 10
ethernet oam link-monitor receive-crc threshold high 15
ethernet oam link-monitor transmit-crc window 10
ethernet oam link-monitor transmit-crc threshold high 15
ethernet oam link-monitor high-threshold action errordisable-interface
D. ethernet oam link-monitoring global enable
ethernet oam link-monitor receive crc-errors period 15
ethernet oam link-monitor receive crc-errors limit 15
ethernet oam link-monitor transmit crc-errors period 10
ethernet oam link-monitor transmit crc-errors limit 15
ethernet oam link-monitor limit action error-disable interface

Answer: C

Latest 350-501 Dumps Valid Version with 248 Q&As

Latest And Valid Q&A | Instant Download | Once Fail, Full Refund

Subscribe