Which action resolves the issue?

An engineer configures FCoE between a set of ESXi hosts and a Cisco Nexus 5000 Series Switch. The Converged Network Adapter of the host fails to receive the response from the Cisco Nexus device. Also, the VFC interface is in a down state and the FIP adapter fails to receive 802.1q tagged frames. The host interface is configured for VLAN trunking.

Which action resolves the issue?
A . Activate the reception of Xoff pause frames from the server
B. Configure the UF link as a spanning-tree edge port
C. Enable the active STP port state on the bound Ethernet interface
D. Set the bound Ethernet trunk interface to non-FCoE native VLAN

Answer: D