What must be done to enable dedicated FC connectivity for this HPE Synergy frame?

Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.

What must be done to enable dedicated FC connectivity for this HPE Synergy frame?
A . A second CPU must be installed for all HPE Synergy 480 Gen10 compute nodes.
B. For Brocade switches, a logical interconnect group must be created in HPE OneView.
C. For VC-FC modules, all of server facing ports must be property licensed.
D. SAS switches must be moved to second fabric and FC modules Installed in the first one.

Answer: D

Which statement about this solution is true?

Your customer plans to deploy VMware vSAN using D3940 Storage Modules.

Which statement about this solution is true?
A . The 12Gb SAS modules required for D3940 connectivity can only be installed in the first fabric.
B. To use the storage controller that will access D3940 storage modules, a second CPU must be installed.
C. For VMware vSAN deployment, all drives in the D3940 storage modules must be SSD drives.
D. All drives in the D3940 storage modules must formulate a single logical drive with RAID5 configured

Answer: A

Which interconnects are required to support this connection?

You need to configure a RoCE network to enable lossless networking for HPE J2000 Flash Enclosure support.

Which interconnects are required to support this connection? (Select two.)
A . HPE Virtual Connect SE 40Gb F8 Module for HPE Synergy
B. HPE Virtual Connect SE 16Gb FC Module for HPE Synergy
C. HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy
D. HPE Virtual Connect SE 32Gb FC Module for HPE Synergy
E. Brocade 16Gb Fibfe Channel SAN Switch Module for HPE Synergy
F. Brocade 32Gb Fibre Channel SAN Switch Module for HPE Synergy

Answer: B,D

What should you check to fix the issue?

You are troubleshooting an HPE OneView server profile that presents a critical state. The server profile was configured with a Link Aggregation Group

What should you check to fix the issue?
A . if both FiexNICs are configured with the same speed
B. If the logical enclosure is built on at least three HPE Synergy frames
C. if both FiexNICs are connected to different networks
D. if the logical enclosure is configured with redundant master modules

Answer: A

Which statement about login redistribution is true?

Which statement about login redistribution is true?
A . Login redistribution is available only If HPE Primera or HPE Alletra is connected directly to the HPE Synergy frame
B. Login redistribution is a licensed feature and the number of licenses required depends on the number of active ports
C. Login redistribution is supported only on the HPE Synergy Virtual Connect SE 32Gb FC Modules
D. Login redistribution is used for login balancing when they are not distributed evenly over the FC links

Answer: C