Which of the following functions is NOT supported by agents on SoftConsole?

Which of the following functions is NOT supported by agents on SoftConsole?A . Show idle or busyB . Adjust the sequence of incoming calls in a call queueC . Send instant messagesD . Transfer callsView AnswerAnswer: C

March 2, 2019 No Comments READ MORE +

If you hear the prompt "The number you dial does not exist" when call an inner-office user, the possible reason is (). (Multiple Choice)

If you hear the prompt "The number you dial does not exist" when call an inner-office user, the possible reason is (). (Multiple Choice)A . The maxlength of the corresponding inter prefix is set too short.B . Trunk fault.C . The dialed number is not configured.D . U1900 MTU board...

February 1, 2019 No Comments READ MORE +

When two U1900 unified gateways need to form a two-node cluster, the device version, card, and

When two U1900 unified gateways need to form a two-node cluster, the device version, card, and slot sequence of the two U1900 unified gateways must be same.A . TRUEB . FALSEView AnswerAnswer: A

January 18, 2019 No Comments READ MORE +

If you hear the prompt "The number you dial does not exist" when call an inner-office user, the possible reason is (). (Multiple Choice)

If you hear the prompt "The number you dial does not exist" when call an inner-office user, the possible reason is (). (Multiple Choice)A . The maxlength of the corresponding inter prefix is set too short.B . Trunk fault.C . The dialed number is not configured.D . U1900 MTU board...

January 17, 2019 No Comments READ MORE +

Which of the following signaling protocols are categorized as Common Channel Signaling (CCS)? (Multiple Choice)

Which of the following signaling protocols are categorized as Common Channel Signaling (CCS)? (Multiple Choice)A . SS7B . PRAC . R2D . SIPView AnswerAnswer: AB

January 8, 2019 No Comments READ MORE +

Which of the following statements is CORRECT about the automatic switchboard configuration of U1960?

Which of the following statements is CORRECT about the automatic switchboard configuration of U1960?A . The automatic switchboard number can be the same as a user's short number or long number, because the priority of the automatic switchboard service is higher than that of calls for common users.B . The...

January 8, 2019 No Comments READ MORE +

If you hear the prompt "The number you dial does not exist" when call an inner-office user, the possible reason is (). (Multiple Choice)

If you hear the prompt "The number you dial does not exist" when call an inner-office user, the possible reason is (). (Multiple Choice)A . The maxlength of the corresponding inter prefix is set too short.B . Trunk fault.C . The dialed number is not configured.D . U1900 MTU board...

January 1, 2019 No Comments READ MORE +

Which of the following statements is CORRECT about call rights and user rights on U1900?

Which of the following statements is CORRECT about call rights and user rights on U1900?A . User rights are configured during prefix configuration.B . The international call right can be used only for configuring the outgoing prefix.C . The international call right can be used for configuring prefixes only starting...

December 29, 2018 No Comments READ MORE +

Which of the following statements is INCORRECT about the mode for obtaining the IAD IP address?

Which of the following statements is INCORRECT about the mode for obtaining the IAD IP address?A . Set a static IP address for the IAC . Dynamically obtain the IP address through DHCE . Allow eSight to deliver the IAD IP address.F . Obtain the IP address through PPPoView AnswerAnswer:...

December 17, 2018 No Comments READ MORE +

Which of the following boards is the main control board of an IAD?

Which of the following boards is the main control board of an IAD?A . CVPB . OSUC . ASID . MCUView AnswerAnswer: A

December 10, 2018 No Comments READ MORE +