How many nodes are in the base enclosure?

How many nodes are in the base enclosure?
A . 2 nodes configured as Active-Standby
B . 1 node with duel connectivity
C . 1 node with high availability enabled
D . 2 nodes configured as Active-Active

Answer: D

Explanation:

Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-hwg/base-enclosure- component-overview?guid=guid-7914a554-6943-402e-bd38-3e893163657e&lang=en-us

When a Dell EMC PowerStore node powers up in service mode, what are the commands and sequence used from the appliance SSH client to restore the node back to normal?

When a Dell EMC PowerStore node powers up in service mode, what are the commands and sequence used from the appliance SSH client to restore the node back to normal?
A . svc_rescue_state clear
svc_node reboot

B . svc_node restart
svc_rescue_state start
C . svc_rescue_state normal
svc_node start
D . svc_node shutdown
svc_rescue_state clear

Answer: A

Which formats are available to list alerts?

Which formats are available to list alerts?
A . Standard, NVP, CSV and JSON
B . Table, XLS, CSV and JSON
C . Table, NVP, CSV and XLS
D . Table, NVP, CSV and JSON

Answer: D

Explanation:

https://downloads.dell.com/manuals/common/pwrstr-clirefg_en-us.pdf (output)

The default output format is table, as shown on the previous tab. You can also show events or alerts in name-value pair (NVP), comma-separated values (CSV), or JavaScript Object Notation (JSON). NVP format shows the full value of each field name and its value,

What describes the power requirements for Dell EMC PowerStore?

What describes the power requirements for Dell EMC PowerStore?
A . Lower model numbered systems require less AC line current than higher model numbered systems
B . T models require less total power than X models
C . X models require less total power than T models
D . Lower model numbered systems require less input voltage (VAC) than higher model numbered systems

Answer: A

Explanation:

Maximum input power 240 VAC ± 10%, single phase For 100-120V, a customer-supplied step-up transformer is required AC Line Current (operating maximum at 200 VAC) 8.1 A 8.1 A 9.0 A 9.0 A 9.3 A 10.4 A https://www.dell.com/support/manuals/en-us/powerstore-5000/pwrstr-plang/power-requirements-for-powerstore-x-model-and-powerstore-t-model?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us

Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore/pwrstr-plang/power-requirements?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us

What is the result of the network configuration show for a Dell EMC PowerStore T node A management port?

Refer to the exhibit.

What is the result of the network configuration show for a Dell EMC PowerStore T node A management port?
A . VLAN 1 and VLAN 1501 pass tagged traffic
B . VLAN 1 passes tagged traffic, VLAN 1501 passes untagged traffic
C . VLAN 1 passes untagged traffic, VLAN 1501 passes tagged traffic
D . VLAN 1 and VLAN 1501 pass untagged traffic

Answer: C