Through which network do external hosts connect to the cluster for data access?
A . Management
B . ICM
C . ICD
D . Storage
Answer: D
Explanation:
https://topics-cdn.dell.com/pdf/pwrstr-hcg_en-us.pdf
Through which network do external hosts connect to the cluster for data access?
A . Management
B . ICM
C . ICD
D . Storage
Answer: D
Explanation:
https://topics-cdn.dell.com/pdf/pwrstr-hcg_en-us.pdf
How many nodes are in the base enclosure?
A . 2 nodes configured as Active-Standby
B . 1 node with duel connectivity
C . 1 node with high availability enabled
D . 2 nodes configured as Active-Active
Answer: D
Explanation:
Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-hwg/base-enclosure- component-overview?guid=guid-7914a554-6943-402e-bd38-3e893163657e&lang=en-us
When a Dell EMC PowerStore node powers up in service mode, what are the commands and sequence used from the appliance SSH client to restore the node back to normal?
A . svc_rescue_state clear
svc_node reboot
B . svc_node restart
svc_rescue_state start
C . svc_rescue_state normal
svc_node start
D . svc_node shutdown
svc_rescue_state clear
Answer: A
Which network is used for internal communication?
A . Intra-Cluster Data
B . Intra-Cluster Management
C . NAD Network
D . Inter-Node Network
Answer: B
Which formats are available to list alerts?
A . Standard, NVP, CSV and JSON
B . Table, XLS, CSV and JSON
C . Table, NVP, CSV and XLS
D . Table, NVP, CSV and JSON
Answer: D
Explanation:
https://downloads.dell.com/manuals/common/pwrstr-clirefg_en-us.pdf (output)
The default output format is table, as shown on the previous tab. You can also show events or alerts in name-value pair (NVP), comma-separated values (CSV), or JavaScript Object Notation (JSON). NVP format shows the full value of each field name and its value,
What is a step in configuring the ToR data switches for a Dell EMC PowerStore T?
A . Configure a port for the discovery laptop
B . Create VLANs for NAS servers
C . Create VLAN for vMotion networks
D . Configure ports for management on native VLAN
Answer: A
What describes the power requirements for Dell EMC PowerStore?
A . Lower model numbered systems require less AC line current than higher model numbered systems
B . T models require less total power than X models
C . X models require less total power than T models
D . Lower model numbered systems require less input voltage (VAC) than higher model numbered systems
Answer: A
Explanation:
Maximum input power 240 VAC ± 10%, single phase For 100-120V, a customer-supplied step-up transformer is required AC Line Current (operating maximum at 200 VAC) 8.1 A 8.1 A 9.0 A 9.0 A 9.3 A 10.4 A https://www.dell.com/support/manuals/en-us/powerstore-5000/pwrstr-plang/power-requirements-for-powerstore-x-model-and-powerstore-t-model?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us
Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore/pwrstr-plang/power-requirements?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us
Refer to the exhibit.
What is the result of the network configuration show for a Dell EMC PowerStore T node A management port?
A . VLAN 1 and VLAN 1501 pass tagged traffic
B . VLAN 1 passes tagged traffic, VLAN 1501 passes untagged traffic
C . VLAN 1 passes untagged traffic, VLAN 1501 passes tagged traffic
D . VLAN 1 and VLAN 1501 pass untagged traffic
Answer: C
How can the PUHC health check results be viewed?
A . By accessing the Swagger UI
B . From syslog server
C . In Details of Appliances and Nodes
D . From management DB
Answer: A
Which option is used when running the journalctl command to query log messages regardless of capitalization?
A . option –casesensitive=YES/NO
B . option -quotes
C . option -ignorecase
D . option –casesensitive=TRUE/FALSE
Answer: D
Explanation:
https://dl.dell.com/topicspdf/pwrstr-ssg_en-us.pdf