On plan A12 what occupant load factor would you use?

Exhibit. On plan A12 what occupant load factor would you use?A . 30 ft2 (2 8 m2)B . 50 ft2 (4 6 m2)C . 100 ft2 (9 3 m2)D . 200 ft2 (18 6 m2)View AnswerAnswer: A Explanation: On plan A12, the occupant load factor to use is 30 ft²...

March 20, 2025 No Comments READ MORE +

For the included figure, which dimension is the tread depth?

Exhibit. For the included figure, which dimension is the tread depth?A . AB . BC . CD . A+BView AnswerAnswer: B Explanation: The tread depth is the horizontal distance from the front edge of a stair tread to the back edge of the same tread, which corresponds to dimension "B"...

March 19, 2025 No Comments READ MORE +

Draperies and decorations in day care occupancies shall comply with the provisions of which NFPA document?

Draperies and decorations in day care occupancies shall comply with the provisions of which NFPA document?A . NFPA701B . NFPA7Q3C . NFPA 704D . NFPA 705View AnswerAnswer: A Explanation: According to NFPA 101, Life Safety Code, draperies, curtains, and other similar furnishings and decorations in day care occupancies must comply...

March 16, 2025 No Comments READ MORE +

What is the maximum travel distance to a single means of egress from a shoe store, if the store is not sprinklered and is less than 2.800 ft2 (260 m2) in size?

What is the maximum travel distance to a single means of egress from a shoe store, if the store is not sprinklered and is less than 2.800 ft2 (260 m2) in size?A . 25 ft (8 m)B . 50 ft (15 m)C . 75 ft (23 m)D . 100 ft...

March 12, 2025 No Comments READ MORE +

The responsibility to promulgate rules that cover plan review is established by

The responsibility to promulgate rules that cover plan review is established byA . NFPA 1.B . NFPA 101.C . NFPA 170.D . NFPA 220.View AnswerAnswer: A Explanation: The responsibility to promulgate rules covering plan review is established by NFPA 1, Fire Code. NFPA 1 provides guidelines and regulations for the...

March 10, 2025 No Comments READ MORE +

What is the residual pressure according to the water supply graph?

Exhibit. What is the residual pressure according to the water supply graph?A . 20 psi (138 kPa)B . 42 psi (290 kPa)C . 80 psi (552 kPa)D . 120 psi (827 kPa)View AnswerAnswer: B Explanation: To determine the residual pressure from the provided water supply graph, locate the appropriate point...

March 7, 2025 No Comments READ MORE +

What is the occupant load of the stage on plan A5?

Exhibit. What is the occupant load of the stage on plan A5?A . 56 peopleB . 58 peopleC . 60 peopleD . 62 peopleView AnswerAnswer: B

March 6, 2025 No Comments READ MORE +

Actuation of alarm notification appliances at the protected premises shall occur within how many seconds after the activation of an initiating device?

Actuation of alarm notification appliances at the protected premises shall occur within how many seconds after the activation of an initiating device?A . 10 secondsB . 30 secondsC . 60 secondsD . 90 secondsView AnswerAnswer: A Explanation: According to NFPA 72, National Fire Alarm and Signaling Code, the actuation of...

March 3, 2025 No Comments READ MORE +

Exhibit

Exhibit. A code is generally considered as a document on what must be done, whereas a standard describesA . in less specificity what is required.B . the enforcing agencies requirementsC . the goals and objectives of a requirementD . in specific detail how it is to be doneView AnswerAnswer: D...

March 1, 2025 No Comments READ MORE +

Fire department access roads shall extend to within what distance of a single exterior door providing access to the interior of a building?

Fire department access roads shall extend to within what distance of a single exterior door providing access to the interior of a building?A . 20 ft (6 m)B . 30 ft (9 m)C . 40 ft (12 m)D . 50 ft (15 m)View AnswerAnswer: D Explanation: According to NFPA 1,...

February 25, 2025 No Comments READ MORE +