Draperies and decorations in day care occupancies shall comply with the provisions of which NFPA document?
Draperies and decorations in day care occupancies shall comply with the provisions of which NFPA document?A . NFPA701B . NFPA7Q3C . NFPA 704D . NFPA 705View AnswerAnswer: A Explanation: According to NFPA 101, Life Safety Code, draperies, curtains, and other similar furnishings and decorations in day care occupancies must comply...
What is the maximum travel distance to a single means of egress from a shoe store, if the store is not sprinklered and is less than 2.800 ft2 (260 m2) in size?
What is the maximum travel distance to a single means of egress from a shoe store, if the store is not sprinklered and is less than 2.800 ft2 (260 m2) in size?A . 25 ft (8 m)B . 50 ft (15 m)C . 75 ft (23 m)D . 100 ft...
The responsibility to promulgate rules that cover plan review is established by
The responsibility to promulgate rules that cover plan review is established byA . NFPA 1.B . NFPA 101.C . NFPA 170.D . NFPA 220.View AnswerAnswer: A Explanation: The responsibility to promulgate rules covering plan review is established by NFPA 1, Fire Code. NFPA 1 provides guidelines and regulations for the...
What is the residual pressure according to the water supply graph?
Exhibit. What is the residual pressure according to the water supply graph?A . 20 psi (138 kPa)B . 42 psi (290 kPa)C . 80 psi (552 kPa)D . 120 psi (827 kPa)View AnswerAnswer: B Explanation: To determine the residual pressure from the provided water supply graph, locate the appropriate point...
What is the occupant load of the stage on plan A5?
Exhibit. What is the occupant load of the stage on plan A5?A . 56 peopleB . 58 peopleC . 60 peopleD . 62 peopleView AnswerAnswer: B
Actuation of alarm notification appliances at the protected premises shall occur within how many seconds after the activation of an initiating device?
Actuation of alarm notification appliances at the protected premises shall occur within how many seconds after the activation of an initiating device?A . 10 secondsB . 30 secondsC . 60 secondsD . 90 secondsView AnswerAnswer: A Explanation: According to NFPA 72, National Fire Alarm and Signaling Code, the actuation of...
Exhibit
Exhibit. A code is generally considered as a document on what must be done, whereas a standard describesA . in less specificity what is required.B . the enforcing agencies requirementsC . the goals and objectives of a requirementD . in specific detail how it is to be doneView AnswerAnswer: D...
Fire department access roads shall extend to within what distance of a single exterior door providing access to the interior of a building?
Fire department access roads shall extend to within what distance of a single exterior door providing access to the interior of a building?A . 20 ft (6 m)B . 30 ft (9 m)C . 40 ft (12 m)D . 50 ft (15 m)View AnswerAnswer: D Explanation: According to NFPA 1,...
What is the approximate maximum available water indicated on supply graph 2 on plan F0.2?
Exhibit. What is the approximate maximum available water indicated on supply graph 2 on plan F0.2?A . 980 gpm (3,709 Ipm)B . 1,680 gpm (6,359 Ipm)C . 1.980 gpm (7,495 Ipm)D . 3,980 gpm (15,066lpm)View AnswerAnswer: C Explanation: The graph labeled as "Water Supply Graph N°2" presents a standard water...
What is the maximum heat release rate of a single fuel package containing foamed plastics that is part of an exhibit booth'?
What is the maximum heat release rate of a single fuel package containing foamed plastics that is part of an exhibit booth'?A . 50 kWB . 75 kWC . 100 kWD . 150 kWView AnswerAnswer: C Explanation: According to NFPA 1031, which covers the qualifications for professionals in fire safety...