What is the issue?

A customer is configuring an upstream disjoint Layer 2 network in a Cisco UCS domain. So far they have configured the following: - Fabric Interconnects are in switching mode. - There is symmetrical configuration for high availability. - There are no overlapping VLANs. - Each vNIC is communicating with one...

January 11, 2020 No Comments READ MORE +

Which command on the Fabric Interconnect displays packet statistics for a given QoS group and MTU size?

Which command on the Fabric Interconnect displays packet statistics for a given QoS group and MTU size?A . show policy-map interface ethernet x/yB . show queuing interface ethernet x/yC . show interface ethernet x/yD . show class-map type qos E . show interface queuing ethernet x/yView AnswerAnswer: B

January 11, 2020 No Comments READ MORE +

Using RBAC for security in a Cisco UCS environment, what is seen in the exhibit?

Refer to the exhibit. Using RBAC for security in a Cisco UCS environment, what is seen in the exhibit?A . custom roleB . default roleC . LDAP group mapD . external service profileView AnswerAnswer: B

January 10, 2020 No Comments READ MORE +

Which two of these represent the correct way to bind VSAN 11 to interface vfc5 attached to interface Ethernet 1/5?

You are troubleshooting an FCoE SAN boot issue on a Cisco UCS C240 M3 server with a VIC 1225. Which two of these represent the correct way to bind VSAN 11 to interface vfc5 attached to interface Ethernet 1/5? (Choose two.)A . 5548UP(config)# int vfc 5 5548UP(config-if)# bind interface Ethernet1/5...

January 10, 2020 No Comments READ MORE +

Which type of power policy is shown when referring to a Cisco UCS environment?

Refer to the exhibit. Which type of power policy is shown when referring to a Cisco UCS environment?A . chassisB . blade serverC . fabric interconnectD . globalE . switchView AnswerAnswer: D

January 10, 2020 No Comments READ MORE +

Why is the dynamic vNIC policy required?

A customer is configuring the dynamic vNIC connection policy in a Cisco UCS domain. Why is the dynamic vNIC policy required?A . It is only required if you are configuring VM-FEC . It is only required if you are configuring Adapter-FEE . It is mainly for the Cisco UCS Manager...

January 9, 2020 No Comments READ MORE +

If you had been monitoring traffic on an original dynamic vNIC, what must you do when the server comes back up?

After migrating a server that is configured with dynamic vNICs, Cisco UCS Manager assigns new dynamic vNICs to the server. If you had been monitoring traffic on an original dynamic vNIC, what must you do when the server comes back up?"A . Reassign the dynamic vNIC back to the old...

January 9, 2020 No Comments READ MORE +

Hotspot Question II

Hotspot Question II View AnswerAnswer:

January 9, 2020 No Comments READ MORE +

What could be the reason pings are not seen in the capture and the KVM is failing to load?

A UCS Admin is trying to launch the KVM console but it is failing to launch. All IP Pools for mgmt are configured and the CIMC has an address in UCSM. They SSH to the fabric Interconnect and run an ethanalyzer while issuing a ping from their local PC to...

January 8, 2020 No Comments READ MORE +

The Cisco UCS Manager displays FSM information for which four of these? (Choose four.)

The Cisco UCS Manager displays FSM information for which four of these? (Choose four.)A . which FSM task is being executedB . the current state of an FSM taskC . the status of the previous FSM taskD . any error codes returned while processingE . all completed FSM tasksF ....

January 8, 2020 No Comments READ MORE +