After conducting the annual test of a dry barrel hydrant, what is the maximum length of time permitted for full drainage to take place?

After conducting the annual test of a dry barrel hydrant, what is the maximum length of time permitted for full drainage to take place?A . 10 minutesB . 15 minutesC . 30 minutesD . 60 minutesView AnswerAnswer: B Explanation: Dry barrel hydrants must be tested annually to ensure proper drainage...

March 3, 2025 No Comments READ MORE +

In occupancies where a Class A or Class B interior finish is required, which of the following is the allowable amount of Class C materials?

In occupancies where a Class A or Class B interior finish is required, which of the following is the allowable amount of Class C materials?A . 5 percentB . 10 percentC . 15 percentD . 20 percentView AnswerAnswer: B Explanation: The use of interior finish materials is regulated by NFPA...

March 1, 2025 No Comments READ MORE +

For the purpose of sprinkler design, a warehouse with moderately combustible contents stored to heights of 12 ft (3.6 m) is classified as an

For the purpose of sprinkler design, a warehouse with moderately combustible contents stored to heights of 12 ft (3.6 m) is classified as anA . Ordinary hazard (Group 1).B . Ordinary hazard (Group 2).C . Extra hazard (Group 1).D . Extra hazard (Group 2).View AnswerAnswer: B Explanation: The classification of...

March 1, 2025 No Comments READ MORE +

What is the minimum static pressure drop required when flow testing fire hydrants?

What is the minimum static pressure drop required when flow testing fire hydrants?A . 5 percentB . 10 percentC . 15 percentD . 20 percentView AnswerAnswer: B Explanation: When performing a fire hydrant flow test, a minimum static pressure drop is required to ensure that the test provides accurate and...

February 19, 2025 No Comments READ MORE +

Which of the following conditions gives an inspector the right to enter a private dwelling to conduct a fire inspection?

Which of the following conditions gives an inspector the right to enter a private dwelling to conduct a fire inspection? I. The consent of the occupant II. Possession of a warrant authorizing entry III. A written complaint from a citizen regarding the property in question IV. When emergency existsA ....

February 17, 2025 No Comments READ MORE +

Where shall fire department connections on wet-pipe automatic sprinkler systems be located?

Where shall fire department connections on wet-pipe automatic sprinkler systems be located?A . On the system side of the water supply check valveB . On the suction side of booster pumpsC . On the supply side of the check valve in a single-riser systemD . Above the dry-pipe valve on...

February 13, 2025 No Comments READ MORE +

A permit shall be required to store more than how many tires outside?

A permit shall be required to store more than how many tires outside?A . 200B . 300C . 400D . 500View AnswerAnswer: C Explanation: The outdoor storage of tires is regulated because tires pose significant fire hazards due to their combustibility and difficulty in extinguishment. According to NFPA 1, Fire...

February 6, 2025 No Comments READ MORE +

The authorization to issue permits is granted by the

The authorization to issue permits is granted by theA . state legislature.B . authority having jurisdiction.C . Fire Inspection Handbook.D . NFPA 101, Life Safety Code.View AnswerAnswer: B Explanation: The authority having jurisdiction (AHJ) is the entity responsible for enforcing codes, standards, and regulations, including the authorization to issue permits....

February 4, 2025 No Comments READ MORE +

The appropriateness of the safeguards required by the Life Safety Code to individual buildings and structures bears due regard to all EXCEPT which of the following?

The appropriateness of the safeguards required by the Life Safety Code to individual buildings and structures bears due regard to all EXCEPT which of the following?A . Age of the buildingB . The fire load of the occupancyC . Number of persons exposedD . Capabilities of the occupantsView AnswerAnswer: A...

February 2, 2025 No Comments READ MORE +

To transfer Class I flammable liquids by pressurizing the tank, which of the following conditions must be met?

To transfer Class I flammable liquids by pressurizing the tank, which of the following conditions must be met? I. Inert gas is used to pressurize the tank. II. Air is used to pressurize the tank. III. A pressure relief device shall be provided. IV. An interlock shall be installed on...

February 1, 2025 No Comments READ MORE +