An HPE customer wants to perform is simplified update of firmware and drivers among their 100 HPE Gen9 and Gen10 racked servers.

An HPE customer wants to perform is simplified update of firmware and drivers among their 100 HPE Gen9 and Gen10 racked servers.

Which HPE software tool should the customer use to minimize the time required to perform this activity.
A . HPE Smart Update Manager
B . HPE OneView Standard
C . HPE ProLiant Support Pack
D . HPE iLO Amplifier Pack

Answer: D

Explanation:

Reference: https://www.hpe.com/us/en/servers/smart-update.html

Given the configuration above, what should happen to any untagged traffic coming from the VMware ESXI host?

You configured a port on an HPE FiexFabric 5900 series switch that is connected to a VMware ESXi server to support multiple VLANs

interface Ten-GigabitEthernet 1/0/11 description server ESXiOl-ethl port link-type trunk port trunk permit vlan 50 port trunk permit vlan 2 port trunk pvid vlan 50

Given the configuration above, what should happen to any untagged traffic coming from the VMware ESXI host?
A . It will be transmitted in vlan 1.
B . It will be dropped
C . It will be transmitted in vlan 2
D . It will be transmitted in vlan 50.

Answer: D

What should you do to ensure storage access is not interrupted when doing the next update?

Refer to the exhibit.

When performing a code upgrade on an HPE Nimble array, you noticed a connection failure on ESX1. Refer to the exhibit showing the complete zoning configuration of one of the HPE SN3000B switches.

What should you do to ensure storage access is not interrupted when doing the next update?
A . Create and ISL between the two HPE SN3000B switches.
B . Create a new zone for ESX1 and the second storage controller.
C . Change the timeout values on the SN3000B switch.
D . Configure the same zone on a second HPE SN3000

Answer: B

Which HPE product can be used as the primary interface to orchestrate all backup targets and Catalyst copy functions?

A customer’s backup administrator is responsible for maintaining and coordinating all nightly backups of the company’s 30 servers.

Which HPE product can be used as the primary interface to orchestrate all backup targets and Catalyst copy functions?
A . HPE StoreServ
B . Smart Storage Administrator
C . Intelligent Provisioning
D . StoreOnce Management Console

Answer: D

From the output in the exhibit, would could be the issue?

Read the question, and then refer to the exhibit.

<Switch-A>display interface Ten-GigabitEthernet 1/0/1 Ten-GigabitEthernet1/0/1 Current state: Administratively DOWN Line protocol state: DOWN IP packet frame type: Ethernet II, hardware address: d894-03fb-793d Description: Ten-GigabitEthernet1/0/1 Interface Bandwidth: 10000000 kbps Loopback is not set Media type is stack wire, port hardware type is STACK_SFP_PLUS Unknown-speed mode, unknown-duplex mode Link speed type is autonegotiation, link duplex type is autonegotiation Flow-control is not enabled Maximum frame length: 10000 Allow jumbo frames to pass Broadcast max-ratio: 100% Multicast max-ratio: 100% Unicast max-ratio: 100% PVID: 1 MDI type: Automdix Port link-type: Trunk VLAN Passing: 10, 20 VLAN permitted: 10, 20 Trunk port encapsulation: IEEE 802.1q Port priority: 0 Last link flapping: 0 hours 0 minutes 18 seconds Last clearing of counters: Never Peak input rate: 78 bytes/sec, at 2011-03-31 04:55:57 Peak output rate: 15 bytes/sec, at 2011-03-30 23:00:57 Last 300 second input: 0 packets/sec 67 bytes/sec – % Last 300 second output: 0 packets/sec 14 bytes/sec – % Input (total): 62670 packets, 8565340 bytes 0 unicasts, 0 broadcasts, 62670 multicasts, 0 pauses Input (normal): 62670 packets, – bytes 0 unicasts, 0 broadcasts, 62670 multicasts, 0 pauses Input: 0 input errors, 0 runts, 0 giants, 0 throttles 0 CRC, 0 frame, – overruns, 0 aborts C ignored, – parity errors Output (total): 3707 packets, 1294835 bytes 0 unicasts, 0 broadcasts, 3707 multicasts, 0 pauses Output (normal): 3707 packets, – bytes 0 unicasts, 0 broadcasts, 3707 multicasts, 0 pauses Output: 0 output errors, – underruns, – buffer failures 0 aborts, 0 deferred, 0 collisions, 0 late collisions 0 lost carrier, – no carrier

A customer added a new switch to their network. They connected it using interface Ten-GigabitEthernet 1/0/1. They are using VLAN 10 and 20 for the devices in their network.

The new switch was fully operational. Then, the customer experienced a power failure later that day and could not reach any device on the new switch after the power returned.

From the output in the exhibit, would could be the issue?
A . The interface loopback is not set.
B . The interface link-speed and duplex are unknown.
C . The interface is administratively down.
D . The interface is configured for a PVID of VLAN 1.

Answer: D

Explanation:

Reference: https://assets.ext.hpe.com/is/content/hpedam/a00004216enw

What must you do to resolve this issue?

Read the question, and then refer to the exhibit.

<Switch-A>display int Ten-GigabitEthernet 1/0/1 Ten-GigabitEthernet1/0/1 Current state: UP Line protocol state: UP IP packet frame type: Ethernet II, hardware address: d894-03fb-793d Description: Ten-GigabitEthernet1/0/1 Interface Bandwidth: 10000000 kbps Loopback is not set Media type is stack wire, port hardware type is STACK SFP_PLUS 10Gbps-speed mode, full-duplex mode Link speed type is autonegotiation, link duplex type is autonegotiation Flow-control is not enabled Maximum frame length: 10000 Allow jumbo frames to pass Broadcast max-ratio: 100% Multicast max-ratio: 100% Unicast max-ratio: 100% PVID: 1 MDI type: Automdix Port link-type: Trunk VLAN Passing: 10 VLAN permitted: 10 Trunk port encapsulation: IEEE 802.1q Port priority: 0 <SNIP>

An administrator connected a hypervisor to interface Ten-Gigabit Ethernet1/0/1 in a switch. The administrator created virtual machines in VLAN 10 and 20 on the hypervisor. These VLANs are configured to be tagged on the hypervisor.

The administrator found that all the virtual machines within VLAN 20 can communicate with each other, but not to any resource on VLAN 20 outside the hypervisor.

What must you do to resolve this issue?
A . Configure the interface as an access port.
B . Configure the PVID of the interface to be VLAN 20.
C . Permit VLAN 20 on the interface.
D . Configure the interface as an IRF port.

Answer: D