What should the Oracle Redo Log block size be set to in order to prevent log entries from being misaligned by read-modify-write operators for an Oracle Database?
What should the Oracle Redo Log block size be set to in order to prevent log entries from being misaligned by read-modify-write operators for an Oracle Database?A . 4 KbB . 8 KbC . 16 KbD . 24 KbView AnswerAnswer: C
Which I/O elevator setting should be selected for use with XtremIO?
Which I/O elevator setting should be selected for use with XtremIO?A . CfqB . DeadlineC . NoopD . AnticipatoryView AnswerAnswer: B
Which DellEMC technology should recommended to the customer to meet these requirements?
A customer what you to design an XtremIO solution for an Oracle RAC application environment. The customer maintains two data centers and requires replication to a third site for disaster recovery purposes. The solution must be fault tolerant and capable of remaining online during planed and unplanned downtime event due...
What is an accurate statement about the XtremIO XVC refresh operations?
What is an accurate statement about the XtremIO XVC refresh operations?A . Unmount of a production volumn is not requiredB . Only snapshot to production refresh is supportedC . O/S side device scan is not requiredD . Refreshed volumn cannot be resizedView AnswerAnswer: A
Which host OS supports both 512 bytes and 4 KB XtremIO logical block (LB) volumns?
Which host OS supports both 512 bytes and 4 KB XtremIO logical block (LB) volumns?A . VMwareB . LinuxC . IBM AIXD . HP-UXView AnswerAnswer: C
Which host operating system does the Live Optic Collector run on?
Which host operating system does the Live Optic Collector run on?A . Windows and LinuxB . Windows, Linux, Solaris and HPUXC . Windows, Linux, and SolarisD . Windows, Linux, and KVMView AnswerAnswer: B
Which best practices should be used for VDI environments?
You need to design a VDI solution for a customer. Which best practices should be used for VDI environments?A . Align data on 8 kB boundaries. Put the master VM image on an XtremIO LUNB . Align data on 4 kB boundaries. Allocate multiple XtremIO LUNs to each hostC ....
Which XtremIO X2 solution should be recommended to the customer?
A customer has a workload with the following attributes: . Generates 500.000 IOPs . Maximum Bandwindth of 14GB/s Which XtremIO X2 solution should be recommended to the customer?A . 1 X-BrickB . 2 X-BrickC . 3 X-BrickD . 4 X-BrickView AnswerAnswer: B
What is true about the flow control feature when configuring he iSCSI SAN from the host to the XtremIO cluster?
What is true about the flow control feature when configuring he iSCSI SAN from the host to the XtremIO cluster?A . Disable flow control features on the server, switch(s) and array portsB . Enable flow control features on the server and array port onlyC . Enable flow control features on...
At which point is data compressed when a host sends data to the XtremIO Storage system?
At which point is data compressed when a host sends data to the XtremIO Storage system?A . Inline before data is written to the SSDB . Once data is written to the Storage ControllerC . After data is written to the SSDsD . After data is in SSD cacheView AnswerAnswer:...