What is a requirement to operate GPUs in a Dell EMC PowerEdge R740 server?

What is a requirement to operate GPUs in a Dell EMC PowerEdge R740 server?A . All GPU cards must be installed at the same timeB . All GPU cards must be of the same type but can be a different modelC . All GPU cards must be of the same...

February 13, 2024 No Comments READ MORE +

Where is the Asset Tag located on the Dell EMC PowerEdge server?

Where is the Asset Tag located on the Dell EMC PowerEdge server?A . Server chassisB . BIOS settingsC . Dell manufacturing labelD . Pull-out information tabView AnswerAnswer: B

February 12, 2024 No Comments READ MORE +

What happens when the Hardware Root of Trust fails to validate the BIOS?

What happens when the Hardware Root of Trust fails to validate the BIOS?A . Boot Guard switches over to the backup BIOS and logs a warning in the system event log.B . Automated BIOS Recovery process recovers the BIOS from the DUP saved in the control panel.C . The server...

February 12, 2024 No Comments READ MORE +

How should they configure the server and deploy the OS?

A technician is installing Windows Server 2016 on a server with RAID 1 and RAID 5 virtual disks. How should they configure the server and deploy the OS?A . Go to system setup to configure both virtual disks Select the Deploy OS option in the system setup utilityB . Go...

February 12, 2024 No Comments READ MORE +

What should the technician do?

One of the servers in a datacenter is set to use the 1+1 power redundancy option with a hot spare. The server uses 1100W PSUs. An SNMP trap has been sent alerting the technician to a PSU failure. Since this is the "hot spare" PSU, the technician chooses an available,...

February 12, 2024 No Comments READ MORE +

What is the minimum iDRAC license required to perform this task?

A technician needs to install the OS on a server remotely using iDRAC. What is the minimum iDRAC license required to perform this task?A . ExpressB . EnterpriseC . BasicD . Baseboard Management ControllerView AnswerAnswer: B

February 12, 2024 No Comments READ MORE +

What should the technician do to achieve the desired RAID level?

A technician is tasked to perform a RAID Level Migration (RLM) of a RAID 5 array to a RAID 6 array. They back up data and look in iDRAC Storage and find that the current RAID 5 array is sliced into two virtual disks. What should the technician do to...

February 12, 2024 No Comments READ MORE +

Which three steps must a technician take prior to replacing a server component with blue tabs/release? (Choose three.)

Which three steps must a technician take prior to replacing a server component with blue tabs/release? (Choose three.)A . Powers off the serverB . Apply anti-static proceduresC . Hot-swap the componentD . Put the server into maintenance modeE . Remove power cablesView AnswerAnswer: CDE

February 11, 2024 No Comments READ MORE +

Where is the data stored to allow Easy Restore to successfully complete a system board replacement?

Where is the data stored to allow Easy Restore to successfully complete a system board replacement?A . NAND Flash module on the disk drive mid planeB . IDSDM SD cardC . vFlash SD cardD . Serial Flash storage in the server’s front panelView AnswerAnswer: C

February 11, 2024 No Comments READ MORE +

Which export type in iDRAC restores a Server Configuration Profile to a known baseline?

Which export type in iDRAC restores a Server Configuration Profile to a known baseline?A . AdvancedB . ReplacementC . BasicD . CloneView AnswerAnswer: B

February 11, 2024 No Comments READ MORE +