Question #1

A technician is creating a virtual disk in the iDRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016 They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard Only the first 2048 GB on the virtual disk can be partitioned

How should the technician obtain access to the remaining 2 TB (approximately) of storage?

  • A . Use the Lifecycle Controller OS Deployment Wizard to deploy the OS on this server
  • B . Delete the 4 TB virtual disk and create a virtual (boot) disk no larger than 2048 GB
  • C . Upgrade to a newer version of the operating system
  • D . Use F2 to go into the BIOS, change the BIOS boot mode to UEFI, and try again

Reveal Solution Hide Solution

Correct Answer: D
Question #2

Where is the data stored to allow Easy Restore to successfully complete a system board replacement?

  • A . NAND Flash module on the disk drive mid plane
  • B . IDSDM SD card
  • C . vFlash SD card
  • D . Serial Flash storage in the server’s front panel

Reveal Solution Hide Solution

Correct Answer: D
Question #3

A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only "sees" 24 threads in total.

Which setting should the technician change in Processor Settings in the System BIOS?

  • A . System Profile
  • B . Virtualization Technology
  • C . HyperThreading
  • D . Number of Cores per Processor

Reveal Solution Hide Solution

Correct Answer: D
Question #4

What are the default settings used when applying firmware and a configuration to a replaced part using the Lifecycle Controller?

  • A . Firmware: Upgrade to latest available version
    Configuration Apply always
  • B . Firmware Allow version upgrade only
    Configuration: Disabled
  • C . Firmware: Match firmware of replaced part
    Configuration Apply always
  • D . Firmware Disabled
    Configuration Apply only if firmware match

Reveal Solution Hide Solution

Correct Answer: C
Question #5

What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge 14G servers?

  • A . Ensures that the installed operating system is authentic
  • B . Ensures that the server has a valid Service Tag number
  • C . Ensures that no unauthorized BIOS or firmware codes are run
  • D . Ensures that the server boots only when connected to a verified network

Reveal Solution Hide Solution

Correct Answer: C
Question #6

DRAG DROP

Match each status LED indicator on the Dell EMC 14G PowerEdge server with its corresponding condition.

Reveal Solution Hide Solution

Correct Answer:


Question #7

An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment.

The inventory consists of:

The server power configuration will be set for gnd redundancy. The management switch is 1000 Base-T and the top of rack switches 10Gb

What additional component(s) is needed for this configuration?

  • A . Hot-plug power supply, 750 W – qty 1
  • B . Hot-plug power supply, 1100W – qty 1
  • C . Dell Networking, cable, 40GbE (QSFP+) to 4 x 10GbE SFP+ passive copper breakout cable, 3 meters – qty 2
  • D . C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord – qty 2

Reveal Solution Hide Solution

Correct Answer: D
Question #8

What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?

  • A . SupportAssist Enterprise
  • B . iSM
  • C . OpenManage Essentials
  • D . iDRAC9

Reveal Solution Hide Solution

Correct Answer: C
Question #9

DRAG DROP

Refer to the exhibit.

Match each callout to the Dell EMC PowerEdge server model shown.

Reveal Solution Hide Solution

Correct Answer:


Question #10

After completing a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster the expense of slowing users down.

Which setting should be changed?

  • A . Rebuild Rate in the BIOS settings
  • B . System Profile to Performance in the BIOS settings
  • C . System Profile to Performance in the iDRAC GUI
  • D . Rebuild Rate in the iDRAC GUI

Reveal Solution Hide Solution

Correct Answer: D

Question #11

An engineer wants to fully leverage Microsoft Windows Server 2016 for TPM-based guarded host deployment of a 14G server.

Which BIOS settings need to be used for installing the Windows server?

A)

B)

C)

D)

  • A . Option A
  • B . Option B
  • C . Option C
  • D . Option D

Reveal Solution Hide Solution

Correct Answer: D
Question #12

A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.

What action should a technician take to help accomplish this goal?

  • A . Configure servers to access the remote firmware repository
  • B . Enable the Match Firmware of Replaced Part setting in the system BIOS
  • C . Install and configure a repository manager
  • D . Enable the Collect System Inventory On Restart (CSIOR) attribute

Reveal Solution Hide Solution

Correct Answer: B
Question #13

DRAG DROP

Match each RAID level to its characteristic.

Reveal Solution Hide Solution

Correct Answer:


Question #14

A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad 1Gb NIC and redundant power supplies. The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC

What should the technician do to verify iDRAC connectivity on each server?

  • A . iDRAC Datacenter license is installed.
  • B . Ethernet port LOM1 is cabled and the link light is green.
  • C . iDRAC dedicated NIC port is cabled and the link light is green
  • D . iDRAC Enterprise license is installed

Reveal Solution Hide Solution

Correct Answer: B
Question #15

Dell EMC PowerEdge 14G servers support which technology?

  • A . Quicksync 1.0
  • B . Intel Boot Guard
  • C . AMD GuardMI
  • D . iDRAC8

Reveal Solution Hide Solution

Correct Answer: C
Question #16

Which type of access is known as Firmware RACADM on a Dell EMC PowerEdge server?

  • A . Accessing RACADM running the Dell Toolkit
  • B . Accessing RACADM with OpenManage software
  • C . Logging into iDRAC using SSH or Telnet
  • D . Logging into iDRAC through Boot Manager

Reveal Solution Hide Solution

Correct Answer: C
Question #17

A Dell EMC PowerEdge 14G server uses Intel OPTANE DC Persistent Memory in App Direct mode .

What is the minimum size DIMM supported for this type of memory?

  • A . 64 GB
  • B . 128 GB
  • C . 256 GB
  • D . 512 GB

Reveal Solution Hide Solution

Correct Answer: B
Question #18

A technician needs to change the iDRAC password on a Dell EMC PowerEdge 14G server in a lights-out datacenter. The be rebooted because it is in production. The iDRAC is configured with the default credentials

How could the technician change the iDRAC password?

  • A . SupportAssist Enterprise
  • B . iDRAC Web GUI
  • C . OpenManage Server Administrator
  • D . Virtual Console; press F2 after rebooting system

Reveal Solution Hide Solution

Correct Answer: D
Question #19

What is a characteristic of SupportAssist Enterprise on Dell EMC PowerEdge 14G servers?

  • A . Used for customers that want monitoring of fewer than 1,000 server, storage, and networking devices
  • B . Dispatches technical support from Dell for all Dell servers, storage, and networking devices
  • C . Proactive, predictive, and automated support technology to enable faster resolution and reporting
  • D . Includes onsite monitoring and automated collection of system state information

Reveal Solution Hide Solution

Correct Answer: C
Question #20

DRAG DROP

What is the correct order of steps taken during the BIOS/UEFI Recovery process?

Reveal Solution Hide Solution

Correct Answer: