What’s the RECOMMENDED twisted pair cable slack length to be left at the work area outlet location to enable the possibility of future changes in the Horizontal Cabling System?
- A . =0.152 m (0.5 ft)
- B . =0.3 m (1 ft)
- C . =1 m (3 ft)
- D . = 5m (16 40 ft)
Which of the following statements Is CORRECT concerning best practice for horizontal cable management panels?
- A . One RU of management panel for each RU of cable patch panel plus one additional RU of cable management
- B . Two RU of cable management panel for each RU of patch panel
- C . Three RU of cable management panel for each RU of patch panel
- D . Two RUs of management panel for each RU of cable patch panel plus two additional RUs of cable management
Communicating a project’s design and technical specifications to the client and stakeholders is part of the ___________of the project.
- A . scope of work
- B . needs analysis
- C . close out procedure
- D . bidding phase
In a RFI, an ICT distribution designer instructs the contractor to test all the fibers In a PON Installation.
Which of the following testing requirements does the designer include?
- A . Uni-directional 850 nm and 1300 nm
- B . Bi-directional 850 nm and 1300 nm
- C . Uni-directional 1310 nm and 1550 nm
- D . Bi-directional 1310 nm and 1550 nm
When designing a video communications network, which type of video communication link is two-person videoconferencing?
- A . Point-to-multipoint bidirectional
- B . Point-to-multipoint unidirectional
- C . Unidirectional
- D . PTP unidirectional
- E . PTP bidirectional
The ICT distribution designer is hired to design a Telecommunications Room on the third floor of a building. The size of the floor is 20 m by 26 m (92 x 85 It).
What is to be the MINIMUM size of the TR?
- A . Shallow Room, no minimum room size
- B . =3 m (10 ft) by = 2.40 m (8 ft)
- C . =3 m (10 ft) by =2.74 m (9 ft)
- D . =3 m (10 ft) by =3.40 m (11 ft)
During bidding the ICT distribution designer should review the bid responses for compliance and completeness. Afterwards, the designer should report the findings and recommendations to the
- A . construction foreman
- B . legal counsel
- C . stakeholders
- D . technical consultant
DRAG DROP
Identify the core switch(es) and server(s) of the data center in the diagram below by dragging the appropriate term into each box in the diagram.

An RFQ usually provides more detail than RFP in selection material such as
- A . delivery date
- B . color
- C . make
- D . mounting option
A system integration approach of a BAS on to a LAN can usually reduce the cost of cabling-related changes by
- A . 10 to 20 percent
- B . 25 to 40 percent
- C . 45 percent
- D . 50 percent