BICSI RCDD-002 BICSI Registered Communications Distribution Designer – RCDD Online Training
BICSI RCDD-002 Online Training
The questions for RCDD-002 were last updated at Jul 18,2025.
- Exam Code: RCDD-002
- Exam Name: BICSI Registered Communications Distribution Designer - RCDD
- Certification Provider: BICSI
- Latest update: Jul 18,2025
Which of the following is NOT an example of a perimeter pathway?
- A . Furniture pathways
- B . Surface raceways
- C . Multi channel raceways
- D . Under carpet cabling
- E . Raceways integrated within walls
A telecommunications outlet/connector may be provided using all listed below EXCEPT:
- A . Wireless AP connectivity
- B . Balanced twisted-pair outlets
- C . Optical fiber connectors
- D . 4p4c (4 position, 4 contact) connector
A furniture cluster with 26 requires a MINIMUM of how many multiuser telecommunications outlet assembly (MUTOA)?
- A . 1
- B . 2
- C . 3
- D . 4
- E . 5
An open office design is made up of three furniture clusters and contains a total of nine.
How many multiuser telecommunications outlet assemblies (MUTOA) should be in the design?
- A . 1
- B . 3
- C . 4
- D . 6
- E . 9
Which of the following is NOT true about consolidation points?
- A . They are not to be used for direct connections to active equipment.
- B . They allow horizontal cables to be extended into work area pathways.
- C . They are to be terminated on separate connectors for each individual user.
- D . The maximum length of cable from the consolidation point (CP) to the outlet varies by media type.
Which of the following is NOT a type of connector for optical fiber?
- A . LC
- B . ST
- C . SFF
- D . S/FTP
- E . SC
On a project with three small conference rooms, a break room, and twelve private offices, what is the MINIMUM number of telecommunications outlet boxes required?
- A . 16
- B . 24
- C . 28
- D . 40
- E . 46
Assuming the total fill capacity of a pathway is 100 cables (all of the same cable type and size), the MAXIMUM number of cables to be installed during the initial installation, without exceeding the fill ratio is:
- A . 25
- B . 40
- C . 50
- D . 60
In a run requiring 15 m (50 ft) of cable between the floor distributor and the consolidation point, the MAXIMUM length of cable allowed between the CP and the telecommunications outlet is:
- A . 27.4 m (90 ft)
- B . 36.5 m (120 ft)
- C . 45.8 m (150 ft)
- D . 75 m (242 ft)
- E . 90 m (295 ft)
When installing outlet boxes in ten private offices in an area which may prove to be difficult to install future additional telecommunications outlets, the MINIMUM quantity of outlet boxes that should be installed is:
- A . 10
- B . 20
- C . 30
- D . Based on the type of cabling specified