When performing a carbon steel to carbon steel hot tap where the CE of one of the metals is greater than 0.42%, which of the following electrodes should be used?

When performing a carbon steel to carbon steel hot tap where the CE of one of the metals is greater than 0.42%, which of the following electrodes should be used?
A . E7048-H4
B . E7048
C . E7018-A1
D . E7018

Answer: D