Who needs to be surveyed for an in-patient hospital project for Location and Transportation Credit, Alternative Transportation: Option 1. Transportation Survey?
Who needs to be surveyed for an in-patient hospital project for Location and Transportation Credit, Alternative Transportation: Option 1. Transportation Survey?A . People visiting patientsB . Hospital employeesC . Patients being releasedD . Pharmaceutical representativesView AnswerAnswer: B Explanation: The Location and Transportation Credit, Alternative Transportation: Option 1. Transportation Survey, is...
Cooling tower blowdown is necessary because
Cooling tower blowdown is necessary becauseA . too much water in the system is inefficient so its water levels must be loweredB . a buildup of dissolved solids increases conductivity which decreases efficiencyC . excess water treatment chemical levels corrode pipes and bleed-off reduces chemical levelsD . cold temperatures can...
To determine possible credit compliance for Energy and Atmosphere Credit, Advanced Energy Metering, what information needs to be verified?
To determine possible credit compliance for Energy and Atmosphere Credit, Advanced Energy Metering, what information needs to be verified?A . That the meter data is remotely accessibleB . That the meter is capable of storing data for at least 12 monthsC . That the meter(s) can be manually readD ....
Which of the following products qualifies under Materials and Resources Credit, Purchasing - Ongoing?
Which of the following products qualifies under Materials and Resources Credit, Purchasing - Ongoing?A . A product labeled Sustainable SourcedB . An organic product produced within a 500 mi. (805 km) radiusC . A United States Department of Agriculture (USDA) organic food productD . A Protected Harvest certified product purchased...
What is the intent of Indoor Environmental Quality Credit, Daylight and Quality Views?
What is the intent of Indoor Environmental Quality Credit, Daylight and Quality Views?A . To achieve a daylight factor in all spacesB . To provide lighting controls for regularly occupied spacesC . To achieve direct line of site to vision glazing for all building occupantsD . To provide a connection...
Which of the following is a low impact development (LID) technique for rainwater management?
Which of the following is a low impact development (LID) technique for rainwater management?A . Storm inletB . Rain gardenC . Detention basinD . Impervious pavementView AnswerAnswer: B Explanation: Low Impact Development (LID) practices manage stormwater by using natural or man-made systems to filter and recharge stormwater into the ground12....
Which of the following service certifications would assist the existing building in achieving Indoor Environmental Quality Credit, Integrated Pest Management?
A property manager is evaluating various bids from pest management services. Which of the following service certifications would assist the existing building in achieving Indoor Environmental Quality Credit, Integrated Pest Management?A . GreenPro, Ecowise, GreenshieldB . Quality Pro, Ecowise, GreenshieldC . San Francisco Tier 3, CRI, Green SealD . Green...
When conducting the Indoor Environmental Quality Credit, Occupant Comfort Survey what is the minimum percentage of building occupants that must respond?
When conducting the Indoor Environmental Quality Credit, Occupant Comfort Survey what is the minimum percentage of building occupants that must respond?A . 10%B . 20%C . 30%D . 40%View AnswerAnswer: C Explanation: The Indoor Environmental Quality Credit, Occupant Comfort Survey is a tool used to assess the performance and success...
What credit rewards customers who change their normal consumption patterns in response to the varying price of energy over time?
What credit rewards customers who change their normal consumption patterns in response to the varying price of energy over time?A . Energy and Atmosphere Credit, Demand ResponseB . Energy and Atmosphere Credit, Ongoing CommissioningC . Energy and Atmosphere Credit, Advanced Energy MeteringD . Energy and Atmosphere Credit, Green Power and...
What is the allowed maximum tenant space exclusion for Energy and Atmosphere Prerequisite, Minimum Energy Performance?
What is the allowed maximum tenant space exclusion for Energy and Atmosphere Prerequisite, Minimum Energy Performance?A . 10% of the vacant spaceB . 10% of the gross floor areaC . 10% of the project site areaD . 10% of the regularly occupied areaView AnswerAnswer: B Explanation: The LEED AP Operations...