What is the recommended minimum of data LIFs per node for iSCSI in a dual-fabric configuration with four SVMs?

What is the recommended minimum of data LIFs per node for iSCSI in a dual-fabric configuration with four SVMs?A . 8 B.12 C.16 D.4View AnswerAnswer: A

May 18, 2023 No Comments READ MORE +

In this scenario, which component should be verified?

You are asked to troubleshoot performance issues in a customer's SAN environment. After reviewing the NetApp SAN and hosts for best practices, you have narrowed down the issues to the fabric switches. In this scenario, which component should be verified?A . F_port config B.FLOGI database C.loss sig counters D.BB_Credit countersView...

May 18, 2023 No Comments READ MORE +

What is causing the problem?

A company has a 4-node Data ONTAP cluster called cl01. The administrator attempts to create a volume on svm1 and can only select aggregates that are owned by node cl01-01 or cl01-02. What is causing the problem?A . The SVM peering relationship has not been configured with the cl01-03 and...

May 18, 2023 No Comments READ MORE +

In this scenario, which statement is true?

An administrator wants to design an NVMe solution to connect Linux hosts to an ONTAP cluster. The proposed solution uses two Cisco MDS 9396T switches for each fabric in a top-of-rack design. In this scenario, which statement is true?A . Asymmetric Namespace Access requires ONTAP 9.4 and higher. B.NVMe solutions...

May 18, 2023 No Comments READ MORE +

In this scenario, how many 2-port 32 Gb HBA cards do you need per storage controller?

You are planning to implement a 32 Gb FC SAN on a 2-node AFF A700 ONTAP 9.5 cluster. You need to create 112 FC LIFs across the HA pair with a limit of 20 FC LIFs per physical HBA port. In this scenario, how many 2-port 32 Gb HBA cards...

May 18, 2023 No Comments READ MORE +

Which SVM configuration is needed before the customer creates LUNs on the new nodes?

A customer recently added two nodes with FC ports to a 4-node cluster. Which SVM configuration is needed before the customer creates LUNs on the new nodes?A . The FC service needs to be enabled on the data SVM. B. The existing LIFs need to be migrated to the new...

May 17, 2023 No Comments READ MORE +

What caused the problem?

Exhibit: cl01::>igroup show Cvserver svm1 VserverIgroup Protocol OS Type Initiators --------- ------------- ------ -- --------- ----------------- -------------------- svm1 esx_cluster mixed vmware 20:00:00:25:b5:11:a0:01, 20:00:00:25:b5:11:b0:01, iqn.1998-01.com.vmware:esx02 cl01::> A customer is provisioning storage for two ESXi hosts using FCoE with CNA adapters. The customer mapped the LUN to the igroup shown in the...

May 17, 2023 No Comments READ MORE +

Which tool enables you to confirm that this will be a valid addition?

You are asked to increase the size of your existing 4-node FAS8060 cluster running ONTAP 9.7 software with four additional AFF A700 nodes. Which tool enables you to confirm that this will be a valid addition?A . Active IQ OneCollect B. Hardware Universe (HWU) C. Active IQ Config Advisor D....

May 17, 2023 No Comments READ MORE +

Which resource has this information?

An administrator needs to determine the maximum volume size that is supported per operating system. Which resource has this information?A . Interoperability Matrix Tool (IMT) B.OneCollect C.Config Advisor D.Hardware Universe (HWU)View AnswerAnswer: A

May 17, 2023 No Comments READ MORE +

In this scenario, what would be an appropriate test for LUN mobility?

You have an SVM that serves LUNs to your hosts in an FC SAN environment. This SVM runs on a 4-node cluster and has two data LIFs on each node, according to best practices. You just created a LUN and mapped it to your initiators group. The LUN is owned...

May 17, 2023 No Comments READ MORE +