The UPS used by FusionPower (prefabricated power module) is ( ).

The UPS used by FusionPower (prefabricated power module) is ( ).A . UPS5000-E B. UPS5000-A C. UPS5000-H D. PS5000-SView AnswerAnswer: C

September 14, 2022 No Comments READ MORE +

What is the maximum IT load supported by the FusionModule2000 integrated UPS? ( )

What is the maximum IT load supported by the FusionModule2000 integrated UPS? ( )A . 125KW B. 150KW C. 75KW D. 50KWView AnswerAnswer: A

September 13, 2022 No Comments READ MORE +

The row-level chilled water intelligent temperature control product NetCol 5000-C032H adopts the form of running pipes ( )

The row-level chilled water intelligent temperature control product NetCol 5000-C032H adopts the form of running pipes ( )A . Up the tube B. Down the tube C. Pipe up and down D. Side run.View AnswerAnswer: B

September 11, 2022 No Comments READ MORE +

How many cabinets can a single row of FusionModule2000 support? ()

How many cabinets can a single row of FusionModule2000 support? ()A . 48 B. 12 C. 36 D. 24View AnswerAnswer: D

September 10, 2022 No Comments READ MORE +

What is the minimum outdoor ambient temperature that the FusionModule800 air conditioner can support? ( )

What is the minimum outdoor ambient temperature that the FusionModule800 air conditioner can support? ( )A . -20 B. -40 C. 0View AnswerAnswer: B

September 10, 2022 No Comments READ MORE +

"Data Center Design Specifications" GB50174-2017 stipulates that when selecting a site, a cooling data center should have sufficient water sources.

"Data Center Design Specifications" GB50174-2017 stipulates that when selecting a site, a cooling data center should have sufficient water sources.A . Direct ventilation cooling method B. Indirect fresh air cooling method C. Water evaporative cooling method D. Chilled water cooling methodView AnswerAnswer: C

September 10, 2022 No Comments READ MORE +

UPS2000-G 1~3kVA supports ( ) parallel.

UPS2000-G 1~3kVA supports ( ) parallel.A . 0 B. 2 C. 3 D. 4View AnswerAnswer: A

September 10, 2022 No Comments READ MORE +

What are the ways of piping in FusionModule800? ( )

What are the ways of piping in FusionModule800? ( )A . Compatible with up and down pipes B. Down the tube C. Up the tubeView AnswerAnswer: A

September 10, 2022 No Comments READ MORE +

What are the incoming line methods supported by UPS5000-A-400/500K? ( )

What are the incoming line methods supported by UPS5000-A-400/500K? ( )A . Downstream B. Top entry line C. Compatible with upper and lower incoming linesView AnswerAnswer: C

September 9, 2022 No Comments READ MORE +

When the single cell voltage in the battery pack reaches ( ), it means that the battery pack is already in a risky state

When the single cell voltage in the battery pack reaches ( ), it means that the battery pack is already in a risky stateA . 1.67V B. 2.25V C. 2.35V D. 2.42VView AnswerAnswer: D

September 9, 2022 No Comments READ MORE +