Antifreeze systems that contain a backflow preventer between the antifreeze piping and the wet pipe system must be equipped with

Antifreeze systems that contain a backflow preventer between the antifreeze piping and the wet pipe system must be equipped withA . a relief valve.B . a sight glass.C . an accelerator.D . an expansion chamber.View AnswerAnswer: D Explanation: Antifreeze systems equipped with a backflow preventer must include an expansion chamber...

March 26, 2025 No Comments READ MORE +

Which Occupancy Classification is a machine shop considered?

Which Occupancy Classification is a machine shop considered?A . Light HazardB . Ordinary Hazard Group 1C . Ordinary Hazard Group 2D . Extra Hazard Group 1View AnswerAnswer: B Explanation: A machine shop is typically considered an Ordinary Hazard Group 1 occupancy due to the moderate level of fire load, including...

March 23, 2025 No Comments READ MORE +

In a building where the maximum ceiling temperature will be 80°F (26°C), what would be the lowest permissible temperature classification for the sprinklers?

In a building where the maximum ceiling temperature will be 80°F (26°C), what would be the lowest permissible temperature classification for the sprinklers?A . OrdinaryB . HighC . IntermediateD . Extra highView AnswerAnswer: A Explanation: For a building where the maximum ceiling temperature will be 80°F (26°C), the lowest permissible...

March 18, 2025 No Comments READ MORE +

What is the maximum distance an underground main can be installed under the building to the riser location without additional requirements?

What is the maximum distance an underground main can be installed under the building to the riser location without additional requirements?A . 2 ft (0.6 m)B . 5 ft (1.5 m)C . 10 ft (3 m)D . 15 ft (4.6 m)View AnswerAnswer: B Explanation: NFPA standards allow a certain distance...

March 10, 2025 No Comments READ MORE +

What is the maximum floor area that can be protected by a single ordinary hazard sprinkler system?

What is the maximum floor area that can be protected by a single ordinary hazard sprinkler system?A . 25,000 ft2 (2,320 m2)B . 40,000 ft2 (3,720 m2)C . 52,000 ft2 (4,830 m2)D . 70,000 ft2 (6,503 m2)View AnswerAnswer: C Explanation: The maximum floor area on any one floor to be...

March 10, 2025 No Comments READ MORE +

How many sprinklers in a townhome style residential occupancy protected in accordance with NFPA 13D with 24 ft (7.3 m) flat, smooth, and horizontal ceilings, with no beams, are required to be calculated for?

How many sprinklers in a townhome style residential occupancy protected in accordance with NFPA 13D with 24 ft (7.3 m) flat, smooth, and horizontal ceilings, with no beams, are required to be calculated for?A . 1B . 2C . 5D . 10View AnswerAnswer: B Explanation: In residential occupancies like townhomes...

March 5, 2025 No Comments READ MORE +

The flow test of the fire pump must achieve what minimum flow rate and discharge pressure?

Annual testing for a 1,500 gpm (5,677 L/min) at 80 psi (1.4 bar) fire pump supporting an attached sprinkler system demand of 1,800 gpm (6,813 L/min) at 100 psi (6.9 bar) is being conducted. The flow test of the fire pump must achieve what minimum flow rate and discharge pressure?A...

March 1, 2025 No Comments READ MORE +

When using a 1.5 in. (40 mm) outlet on a hose connection, an approved pressure-regulating device shall be installed when the residual pressure exceeds what value?

When using a 1.5 in. (40 mm) outlet on a hose connection, an approved pressure-regulating device shall be installed when the residual pressure exceeds what value?A . 100 psi (6.9 bar)B . 175 psi (12.1 bar)C . 250 psi (17.2 bar)D . 300 pei (20.7 bar)View AnswerAnswer: A Explanation: When...

February 26, 2025 No Comments READ MORE +

What is the maximum floor area that can be protected by a single ordinary hazard sprinkler system?

What is the maximum floor area that can be protected by a single ordinary hazard sprinkler system?A . 25,000 ft2 (2,320 m2)B . 40,000 ft2 (3,720 m2)C . 52,000 ft2 (4,830 m2)D . 70,000 ft2 (6,503 m2)View AnswerAnswer: C Explanation: The maximum floor area on any one floor to be...

February 13, 2025 No Comments READ MORE +

What is the maximum floor area that can be protected by a single ordinary hazard sprinkler system?

What is the maximum floor area that can be protected by a single ordinary hazard sprinkler system?A . 25,000 ft2 (2,320 m2)B . 40,000 ft2 (3,720 m2)C . 52,000 ft2 (4,830 m2)D . 70,000 ft2 (6,503 m2)View AnswerAnswer: C Explanation: The maximum floor area on any one floor to be...

February 12, 2025 No Comments READ MORE +