Which OSHA regulation addresses storage and handling of liquefied petroleum gas?

Which OSHA regulation addresses storage and handling of liquefied petroleum gas?A . 1910.107B . 1910.108C . 1910.110D . 1910.119View AnswerAnswer: C Explanation: OSHA regulation 1910.110 addresses storage and handling of liquefied petroleum gas (LPG). This regulation covers the general requirements for the design, construction, installation, operation, inspection, and maintenance of...

February 4, 2025 No Comments READ MORE +

Heat transfer oils can be used up to

Heat transfer oils can be used up toA . 600° F (315° C).B . 650° F (343° C).C . 700° F (371° C).D . 750° F (399C).View AnswerAnswer: B Explanation: 650° F (343° C). Heat transfer oils are fluids that are used to transfer heat from one source to another...

January 30, 2025 No Comments READ MORE +

Which type of construction consists of structural members of approved noncombustible or limited combustible materials with specified fire resistance ratings for exterior bearing walls of 3 or 4 hours?

Which type of construction consists of structural members of approved noncombustible or limited combustible materials with specified fire resistance ratings for exterior bearing walls of 3 or 4 hours? A. Type I B. Type II C. Type III D. Type IVView AnswerAnswer: A Explanation: The correct answer is A. Type...

January 29, 2025 No Comments READ MORE +

What type of fire pump has a pressure range that can exceed 300 psi (2,068 kPa)?

What type of fire pump has a pressure range that can exceed 300 psi (2,068 kPa)?A . Horizontal-end suctionB . Suction in-lineC . Split caseD . Vertical turbineView AnswerAnswer: B Explanation: Fire pump Explore A suction in-line fire pump has a pressure range that can exceed 300 psi (2,068 kPa)....

January 29, 2025 No Comments READ MORE +

When evaluating the hydraulic properties of water for fire protection system, what is the measurement of a fluid's resistance to flow?

When evaluating the hydraulic properties of water for fire protection system, what is the measurement of a fluid's resistance to flow?A . VelocityB . ViscosityC . PressureD . DensityView AnswerAnswer: B Explanation: The measurement of a fluid’s resistance to flow is calledviscosity. Viscosity is the property of a fluid that...

January 25, 2025 No Comments READ MORE +

Which factor plays a significant role in most industrial fire and explosion losses?

Which factor plays a significant role in most industrial fire and explosion losses?A . ProcessB . MechanicalC . HumanD . ExternalView AnswerAnswer: C Explanation: The answer is C. Human factor plays a significant role in most industrial fire and explosion losses. According to a study by Allianz Global Corporate &...

January 22, 2025 No Comments READ MORE +

Response Time Index (RTI) is a value applicable to

Response Time Index (RTI) is a value applicable toA . Amount of time required for water to reach the most remote sprinkler.B . Measure of thermal sensitivity of the air evacuation device of a dry pipe sprinkler system.C . Measure of thermal sensitivity of a sprinkler's activation.D . Measure of...

January 21, 2025 No Comments READ MORE +