Which command must be configured at the interface level to honor Differentiated Services Code Point (DSCP)-based Class of Service (CoS) on a ICX7750?
- A . qos profile
- B . ip dscp-remark 1
- C . qos-tos map dscp-priority
- D . trust dscp
What are two differences between Class of Service (CoS) and Differentiated Services Code Point (DSCP)? (Choose two.)
- A . DSCP defines priority levels and CoS manipulates traffic according to these defined priority levels.
- B . CoS defines priority levels and DSCP manipulates traffic according to these defined priority levels.
- C . DSCP operates at Layer 2 in OSI model, whereas CoS operates in Layer 3.
- D . CoS operates at Layer 2 in OSI model, whereas DSCP operates in Layer 3.
- E . DSCP is simpler and can scale easily as the network grows. CoS becomes more complex as network demand for prioritized data increase.
Which two ICX switch models are recommended for collapsed aggregation and core network designs? (Choose two.)
- A . ICX7850
- B . ICX7750
- C . ICX7550
- D . ICX7450
- E . ICX7250
Which ICX model can run silently in fanless mode?
- A . ICX7150-48PF
- B . ICX7150-48P
- C . ICX7550-24P
- D . ICX7150-48ZP
A customer required an access switch with a Power over Ethernet (PoE) budget not to exceed 240W. They also require the switch to make no fan noise.
Which ICX switch would fit these requirements?
- A . ICX7150-C12P
- B . ICX7150-24P
- C . ICX7150-48P
- D . ICX7150-C10ZP
If a customer needs to implement VRRP-E on their ICX7550 units, which license needs to be applied to enable this feature?
- A . PoD
- B . MACSec
- C . L3-Base
- D . L3-prem
Which ICX model has eight integrated QSFP28 ports?
- A . ICX7550-48F
- B . ICX7850-48F
- C . ICX7650-48F
- D . ICX7750-48F
Which three factors must be considered when ordering a replacement power supply for an ICX7650? (Choose three.)
- A . 110 vs 220 volt
- B . DC vs AC power
- C . airflow direction
- D . active vs passive cooling
- E . hotswap vs non-hotswap
- F . PoE vs non-PoE
Which switch cannot exceed a maximum of 30W per port?
- A . ICX7650
- B . ICX7550
- C . ICX7150-48ZP
- D . ICX7150-C12P
Which switch model provides the most 100Gb ports?
- A . ICX7850-48F
- B . ICX7850-32Q
- C . ICX7750-32Q
- D . ICX7850-48FS