Which fiber cable end shown in the exhibit is supported on a NetApp E-Series system?

Exhibit: Which fiber cable end shown in the exhibit is supported on a NetApp E-Series system?A . 1B . 2C . 3D . 4View AnswerAnswer: B

August 24, 2021 No Comments READ MORE +

What SANtricity package(s) must be installed on a Windows server when it is acting as both a data host and a storage management host?

What SANtricity package(s) must be installed on a Windows server when it is acting as both a data host and a storage management host?A . The client and agentB . The client, agent, and utilitiesC . The client, failover driver, and agentD . The clientView AnswerAnswer: C

August 24, 2021 No Comments READ MORE +

In this scenario, what are you measuring?

You are helping a customer diagnose a performance issue on an E-Series storage system. You decide to measure the amount of data that is being handled over the span of an hour. In this scenario, what are you measuring?A . IOPSB . I/O alignmentC . parityD . throughputView AnswerAnswer: D

August 24, 2021 No Comments READ MORE +

How many 32 Gb ports are on one FC host interface card (HIC) on the NetApp E2800, EF280, E5700, and EF570 systems?

How many 32 Gb ports are on one FC host interface card (HIC) on the NetApp E2800, EF280, E5700, and EF570 systems?A . 1B . 2C . 4D . 6View AnswerAnswer: C

August 24, 2021 No Comments READ MORE +

Where would you find the version of the driver and firmware for QLogic HBAs that are supported by NetApp E-Series systems?

Where would you find the version of the driver and firmware for QLogic HBAs that are supported by NetApp E-Series systems?A . SANtricity Admin GuideB . Interoperability Matrix ToolC . Hardware UniverseD . QLogic download webpageView AnswerAnswer: B

August 23, 2021 No Comments READ MORE +

What is a best practice recommendation for the automated system monitor? (Choose the best answer.)

What is a best practice recommendation for the automated system monitor? (Choose the best answer.)A . It should only run on one client connected to the storage system.B . It should be stopped during storage system normal operations.C . It should be stopped during a controller firmware upgrade.D . It...

August 23, 2021 No Comments READ MORE +

Where does the explicit multipath driver reside?

Where does the explicit multipath driver reside?A . on the I/O hostB . on the storage manager hostC . host on the storage manager clientD . in the controller's memoryView AnswerAnswer: A

August 23, 2021 No Comments READ MORE +

Which NetApp tool provides information on size, weight, acoustic noise, and power of NetApp E-Series systems?

Which NetApp tool provides information on size, weight, acoustic noise, and power of NetApp E-Series systems?A . Interoperability Matrix ToolB . Hardware UniverseC . Active ICD . Config AdvisorView AnswerAnswer: B

August 23, 2021 No Comments READ MORE +

In this scenario, which two prerequisites are required to complete the setup?

You are setting-up asynchronous mirroring between two E2860 systems. In this scenario, which two prerequisites are required to complete the setup? (choose two)A . both the primary and secondary systems must be using the same subnets for mirroring connectionsB . The secondary system must have 2X the storage capacity of...

August 23, 2021 No Comments READ MORE +

What are two base host connectivity selections that are provided by the E2800 controller? (Choose two.)

What are two base host connectivity selections that are provided by the E2800 controller? (Choose two.)A . FCB . SASC . IBD . iSCSIView AnswerAnswer: AD

August 22, 2021 No Comments READ MORE +