UPS5000-A/E 400KVA and above models are divided into standard version and enhanced version. The standard version is equipped with () isolation switch.
UPS5000-A/E 400KVA and above models are divided into standard version and enhanced version. The standard version is equipped with () isolation switch.A . Main inputB . Bypass InputC . RepairD . OutputView AnswerAnswer: C
Huawei Technologies Co., Ltd. is compliant with GB50174-2008 standard ( ) is compliant with GB50174-2017 standard ( ).
Huawei Technologies Co., Ltd. is compliant with GB50174-2008 standard ( ) is compliant with GB50174-2017 standard ( ).A . Participating units, Auditing unitB . Participating units, participating unitsC . Auditing unit, Auditing unitD . Auditing unit, Participating unitsView AnswerAnswer: C
Considering the low load rate of the UPS system, the UPS5000-E is designed with an intelligent sleep function, which can increase the system load rate and keep the system running efficiently. When the UPS5000E is in intelligent sleep mode, how many power modules are redundant?
Considering the low load rate of the UPS system, the UPS5000-E is designed with an intelligent sleep function, which can increase the system load rate and keep the system running efficiently. When the UPS5000E is in intelligent sleep mode, how many power modules are redundant?A . 2B . 1C ....
What is the energy saving effect of Huawei's Icooling?
What is the energy saving effect of Huawei's Icooling?A . 15%B . 10%C . 8%D . 5%View AnswerAnswer: A
How many poles of circuit breaker are generally used for the external maintenance bypass of UPS system?
How many poles of circuit breaker are generally used for the external maintenance bypass of UPS system?A . 3B . 1C . 4D . 2View AnswerAnswer: A
What is the UPS2000-G 6-20k host operation interface? which can display the system status in real time.
What is the UPS2000-G 6-20k host operation interface? which can display the system status in real time.A . LEDB . LCDC . Touch screenD . Remote network managementView AnswerAnswer: B
When using a single RH5885 server, how many measurement points can the NetEco management system support to achieve centralized management of multiple data centers?
When using a single RH5885 server, how many measurement points can the NetEco management system support to achieve centralized management of multiple data centers?A . 20B . 40C . 50D . 100View AnswerAnswer: A
A project requires the management system to access a third-party generator set, two smart meters (same model), and two precision air conditioners (same model). How many third-party equipment access fees does the management system need to report?
A project requires the management system to access a third-party generator set, two smart meters (same model), and two precision air conditioners (same model). How many third-party equipment access fees does the management system need to report?A . 1B . 3C . 5D . None of the aboveView AnswerAnswer: B
UPS5000-E 100kVA, which of the following input switches is most suitable for the machine?
UPS5000-E 100kVA, which of the following input switches is most suitable for the machine?A . 125AB . 80AC . 160AD . 200AView AnswerAnswer: D
Which of the following descriptions of the eLight function of the intelligent module status indicator in FusionModule2000v3.0 is correct?
Which of the following descriptions of the eLight function of the intelligent module status indicator in FusionModule2000v3.0 is correct?A . The door frame indicator light eLight is only a decorative atmosphere rendering functionB . Door frame indicator lights can be associated with alarm statusC . Door frame indicator light eLight...