UPS2000-G monitors the entire parallel system with one card. The parallel system only needs one communication option card to monitor the entire parallel system.
UPS2000-G monitors the entire parallel system with one card. The parallel system only needs one communication option card to monitor the entire parallel system.A . TrueB . FalseView AnswerAnswer: A
Channel delivery authorization of B2 means that all CSPs at or above the certification level can deliver.
Channel delivery authorization of B2 means that all CSPs at or above the certification level can deliver.A . TrueB . FalseView AnswerAnswer: A
The UPS5000-E power module adopts a fan fault-tolerant design. When two of the fans fail, how much load can the power module still carry?
The UPS5000-E power module adopts a fan fault-tolerant design. When two of the fans fail, how much load can the power module still carry?A . 0.2B . 0.3C . 0.5D . 0.6View AnswerAnswer: B
UPS5000 -A 30~120kVA can support wall installation.
UPS5000 -A 30~120kVA can support wall installation.A . TrueB . FalseView AnswerAnswer: B
The NetEco management system can automatically calculate the electricity expenses of the computer room based on the tiered electricity price strategy.
The NetEco management system can automatically calculate the electricity expenses of the computer room based on the tiered electricity price strategy.A . TrueB . FalseView AnswerAnswer: A
Which of the following models can be equipped with an external large-capacity battery charger for fast recharging?
Which of the following models can be equipped with an external large-capacity battery charger for fast recharging?A . UPS5000-AB . UPS5000-EC . UPS2000-A 6/10K Professional Edition StandardD . UPS2000-G 6K long-termView AnswerAnswer: C
UPS5000-E (50kVA power module) has a single cabinet capacity of 300kVA and can support 8 racks in parallel.
UPS5000-E (50kVA power module) has a single cabinet capacity of 300kVA and can support 8 racks in parallel.A . TrueB . FalseView AnswerAnswer: A
The PDU8000 precision power distribution cabinet uses a 7-inch liquid color touch screen, which can graphically display the power distribution cabinet system diagram and the status of each switch.
The PDU8000 precision power distribution cabinet uses a 7-inch liquid color touch screen, which can graphically display the power distribution cabinet system diagram and the status of each switch.A . TrueB . FalseView AnswerAnswer: A
The UPS5000-E battery adopts a neutral-line-free design, which makes it easy to reuse the old battery when replacing the tower unit.
The UPS5000-E battery adopts a neutral-line-free design, which makes it easy to reuse the old battery when replacing the tower unit.A . TrueB . FalseView AnswerAnswer: B
The basic principles of refrigeration for air-cooled and water-cooled air conditioners are the same
The basic principles of refrigeration for air-cooled and water-cooled air conditioners are the sameA . TrueB . FalseView AnswerAnswer: A