Which of the following cable doesn't OceanStor 18800 product support?

Which of the following cable doesn't OceanStor 18800 product support?A . mini SAS cablesB . SAS cablesC . AOC cableD . FC cableView AnswerAnswer: B

July 1, 2018 No Comments READ MORE +

Which interface card should be configured when Huawei OceanStor 5600 V3 storage inter-engine interconnection expansion?

Which interface card should be configured when Huawei OceanStor 5600 V3 storage inter-engine interconnection expansion?A . PCIEB . 10 GEC . IBD . SmartIOView AnswerAnswer: D

May 18, 2018 No Comments READ MORE +

Which of the following description about Huawei OceanStor V3 cascade 3DC and parallel 3DC is correct? (Multiple Choice)

Which of the following description about Huawei OceanStor V3 cascade 3DC and parallel 3DC is correct? (Multiple Choice)A . No matter parallel 3DC or cascade 3DC, if synchronous replication between sites is recommended to adopt fiber connection, asynchronous replication can be used ISCSI link.B . In Parallel 3DC networking, because...

May 10, 2018 No Comments READ MORE +

IO traffic control technology in SmartQos is based on what mechanism to achieve user performance control objectives (IOPS, bandwidth) for traffic restrictions?

IO traffic control technology in SmartQos is based on what mechanism to achieve user performance control objectives (IOPS, bandwidth) for traffic restrictions?A . SHA256B . SHA1C . Token BucketD . DHTView AnswerAnswer: C

April 24, 2018 No Comments READ MORE +

In synchronous remote replication, about the process of the storage receiving I/O requests issued by the server, which of the following statements is correct?

In synchronous remote replication, about the process of the storage receiving I/O requests issued by the server, which of the following statements is correct?A . First sent to the master Cache, and then sent to the master storage, and then synchronize to the slave Cache by the master storageB ....

April 16, 2018 No Comments READ MORE +

Which of the following is incorrect about Huawei OceanStor V3 converged storage system?

Which of the following is incorrect about Huawei OceanStor V3 converged storage system?A . SAN engines and file engines have a separate architecture.B . By way of parallel dual-stack support both volume (SAN) and file system (NAS).C . Use unified storage pool technology.D . File system can achieve deduplication data...

April 15, 2018 No Comments READ MORE +

When dealing with urgent problems, in order to facilitate the positioning problem, you can use some non-involved access customer’s data's gadgets that are self-developed by the maintenance personnel in their daily work.

When dealing with urgent problems, in order to facilitate the positioning problem, you can use some non-involved access customer’s data's gadgets that are self-developed by the maintenance personnel in their daily work.A . TrueB . FalseView AnswerAnswer: B

February 23, 2018 No Comments READ MORE +

In OceanStor V3 storage system, when configured LUN Copy, can choose different copy speed according to the business characteristics and storage system performance, if try not to affect the equipment performance when copy date, what speed would be the best choice?

In OceanStor V3 storage system, when configured LUN Copy, can choose different copy speed according to the business characteristics and storage system performance, if try not to affect the equipment performance when copy date, what speed would be the best choice?A . Low SpeedB . Medium SpeedC . High SpeedD...

February 17, 2018 No Comments READ MORE +