What is one solution that you can recommend?
A company has a variety of HPE Aruba Networking solutions, including an HPE Aruba Networking infrastructure and HPE Aruba Networking ClearPass Policy Manager (CPPM). The company passes traffic from the corporate LAN destined to the data center through a third-party SRX firewall. The company would like to further protect itself...
For which type of certificate it is recommended to install a CA-signed certificate on the Subscriber before it joins the cluster?
You are establishing a cluster of HPE Aruba Networking ClearPass servers. (Assume that they are running version 6.9.). For which type of certificate it is recommended to install a CA-signed certificate on the Subscriber before it joins the cluster?A . DatabaseB . HTTPSC . RADIUS/EAPD . RadSecView AnswerAnswer: B Explanation:...
How do you start configuring the command list on CPPM?
A company uses HPE Aruba Networking ClearPass Policy Manager (CPPM) as a TACACS+ server to authenticate managers on its AOS-CX switches. The company wants CPPM to control which commands managers are allowed to enter. You see there is no field to enter these commands in ClearPass. How do you start...
What should you set up on the APs to help the solution function correctly?
A company has HPE Aruba Networking APs (AOS-10), which authenticate clients to HPE Aruba Networking ClearPass Policy Manager (CPPM). CPPM is set up to receive a variety of information about clients' profile and posture. New information can mean that CPPM should change a client's enforcement profile. What should you set...
Which devices are responsible for the IPsec encapsulation?
A company is implementing a client-to-site VPN based on tunnel-mode IPsec. Which devices are responsible for the IPsec encapsulation?A . Gateways at the remote clients' locations and devices accessed by the clients at the main siteB . The remote clients and devices accessed by the clients at the main siteC...
What is part of the correct configuration on the AOS-CX switches?
A company has wired VolP phones, which transmit tagged traffic and connect to AOS-CX switches. The company wants to tunnel the phones' traffic to an HPE Aruba Networking gateway for applying security policies. What is part of the correct configuration on the AOS-CX switches?A . UBT mode set to VLAN...
What is part of the correct configuration on the AOS-CX switches?
A company has wired VolP phones, which transmit tagged traffic and connect to AOS-CX switches. The company wants to tunnel the phones' traffic to an HPE Aruba Networking gateway for applying security policies. What is part of the correct configuration on the AOS-CX switches?A . UBT mode set to VLAN...
What is part of the correct configuration on the AOS-CX switches?
A company has wired VolP phones, which transmit tagged traffic and connect to AOS-CX switches. The company wants to tunnel the phones' traffic to an HPE Aruba Networking gateway for applying security policies. What is part of the correct configuration on the AOS-CX switches?A . UBT mode set to VLAN...
Which Type (namespace) should you specify for the rule?
You need to create a rule in an HPE Aruba Networking ClearPass Policy Manager (CPPM) role mapping policy that references a ClearPass Device Insight Tag. Which Type (namespace) should you specify for the rule?A . ApplicationB . TipsC . DeviceD . EndpointView AnswerAnswer: D Explanation: When creating a rule in...
What should you do?
A company is using HPE Aruba Networking ClearPass Device Insight (CPDI) (the standalone application). You have identified a device, which is currently classified as one type, but you want to classify it as a custom type. You also want to classify all devices with similar attributes as this type, both...