Where should the technician perform the Firmware Rollback?

A technician is experiencing a compatibility issue that causes network disconnects between the iDRAC firmware and an application that is running. The iDRAC must be rolled back to the last working version. The Enterprise licensed server cannot be rebooted outside scheduled maintenance windows. The next scheduled window is one month...

December 17, 2018 No Comments READ MORE +

What does the user need to consider?

A user has a fully configured PowerEdge R640 and an iSM installed on their Windows 2016 operating system. They now want to install OMSA to enable them to have alerts sent out in-Band to a management console. What does the user need to consider?A . OMSA can be installed on...

December 6, 2018 No Comments READ MORE +

What method can be used to enable the default login account?

A technician receives a repurposed PowerEdge server. After racking and cabling the server, the technician attempts to log into the iDRAC but cannot do so. The default account has been disabled. What method can be used to enable the default login account?A . Run the racadm recresetcommand from the host...

December 1, 2018 No Comments READ MORE +

What is the result?

A technician creates two virtual disks and assigns a dedicated hot spare to each virtual disk. They also create a global hot spare. A drive fails on the second virtual disk. What is the result?A . Dedicated hot spare for the virtual disk replaces the failed drive.B . Global hot...

November 30, 2018 No Comments READ MORE +

What can a technician do to ensure that no malicious code can be introduced into any of the servers through physical access?

What can a technician do to ensure that no malicious code can be introduced into any of the servers through physical access?A . Set USB 3.0 to disabledB . Set Secure Boot Policy to enabledC . Set User Accessible Ports to disabledD . Set UEFI Variable Acces to disabledView AnswerAnswer:...

November 20, 2018 No Comments READ MORE +

What is the minimum iDRAC license required to perform this task?

A technician needs to install the OS on a server remotely using iDRAC. What is the minimum iDRAC license required to perform this task?A . ExpressB . EnterpriseC . BasicD . Baseboard Management ControllerView AnswerAnswer: B Explanation: Reference https://community.spiceworks.com/topic/514389-dell-idrac-licensing

November 4, 2018 No Comments READ MORE +

What is a recommended way to prepare the disks for the new project?

A technician is setting up a previously used server. Upon power up, the PERC alerts them to the presence of a foreign configuration. In the iDRAC storage section, the technician checks Foreign View. The foreign array configuration is the same as the configuration needed for the new project. What is...

September 17, 2018 No Comments READ MORE +

What is a valid troubleshooting step for this issue?

A technician receives an email alert that one of the drives on a server has failed. Upon replacing the bad drive, they receive a second email alert that the same drive has failed. The technician installs the replacement drive in another server and it works correctly. What is a valid...

September 15, 2018 No Comments READ MORE +

Which memory mode should be configured so that all memory is seen by the OS?

A server is equipped with 2 CPUs and 12x 8 GB DIMMs, for a total of 96 GB. The OS is not seeing all the memory. Which memory mode should be configured so that all memory is seen by the OS?A . MirroringB . Advanced ECCC . OptimizerD . SparingView...

September 15, 2018 No Comments READ MORE +

What troubleshooting steps should the technician take to resolve this issue?

A technician plugs in a server that has dual power supply units. After powering on the system, they notice that the power supply status indicators blink green then turn off. What troubleshooting steps should the technician take to resolve this issue?A . Set the power supply redundancy option to ‘No...

September 14, 2018 No Comments READ MORE +