You need to configure a server that is connected to a Storage Center through iSCSI. You will need to use one or more hardware iSCSI host bus adapters. In addition, if connectivity is lost due to controller failover, the server needs to reconnect to the Storage Center iSCSI target ports.

You need to configure a server that is connected to a Storage Center through iSCSI. You will need to use one or more hardware iSCSI host bus adapters. In addition, if connectivity is lost due to controller failover, the server needs to reconnect to the Storage Center iSCSI target ports.A...

July 2, 2019 No Comments READ MORE +

What is causing the performance issue?

You notice that servers connecting through iSCSI are not performing as expected. After reviewing the graphics, you identify high latency due to an excessive number of retransmissions. What is causing the performance issue?A . System uses the standard MTU sizeB . Switch firmware is out of dateC . VLAN ID...

July 1, 2019 No Comments READ MORE +

What must be considered when installing the I/O card?

You need to physically install an I/O card into an SC9000 storage array. What must be considered when installing the I/O card?A . I/O card BIOS and IPC connectionB . ESD and I/O slot priorityC . I/O slot priority and I/O card BIOSD . IPC connection and ESDView AnswerAnswer: A

June 29, 2019 No Comments READ MORE +

If you continued configuring the controller, what are the reasons why the deployment will fair?

After setting up an SC4020 and turning on the system, both controllers initialize to Safe Mode and are ready for configuration You plug the serial cable into the first controller and type the platform prejoin show command You then receive the command output shown in the exhibit If you continued...

June 28, 2019 No Comments READ MORE +

What is the reason for this issue?

You added an existing Storage Center to an instance of Dell Storage Manager using the Volume Manger user. You are able to map volumes in the 10K folder to the servers but not the volumes in the SSD folder. What is the reason for this issue?A . Only the Administrator...

June 28, 2019 No Comments READ MORE +

Which action will achieve this goal?

You have created a snapshot profile in which one snapshot is taken every 10 minutes with an expiration time set to “1 week”. You goal is to Improve space utilization without changing the 10-minute Interval between the snapshots. Which action will achieve this goal?A . Set the minimum “Allowed Repeat...

June 23, 2019 No Comments READ MORE +

Which exhibit represents the correct iSCSI cabling?

A dual controller SC Series using iSCSI needs to be installed. The site will use two switches/VLANs and run in Virtual Port mode. Which exhibit represents the correct iSCSI cabling? A) B) C) D) A . Option AB . Option BC . Option CD . Option DView AnswerAnswer: D

June 20, 2019 No Comments READ MORE +

Which recommended technology meets these requirements?

A company has multiple Storage Centers at their primary site and a disaster recovery system at their remote site. Because there company has an important volume that request high availability protection, an outage on one system at the primary location must not cause data to be inaccessible. In addition, disaster...

June 20, 2019 No Comments READ MORE +

Which configuration areas should be investigated to prevent future outage?

A company experienced complete storage outages on some of their servers. The outages occurred when network maintenance was performed within their iSCSI network. Which configuration areas should be investigated to prevent future outage?A . Ensure Delayed Acknowledgment has been disabled on the iSCSI adapters. Ensure all server iSCSI adapter are...

June 17, 2019 No Comments READ MORE +

What is causing the connectivity loss during failover?

You are performing failover testing on an FC-attached dual controller SC8000 storage array. You notice that the storage administrator’s Microsoft Windows 2008 R2 servers experience I/O errors. However, the RHEL and ESX servers are not experiencing any problems. All FC HBA time outs are configured based on Dell EMC best...

June 16, 2019 No Comments READ MORE +