Exam4Training

DELL EMC DEA-41T1 Associate – PowerEdge Exam Online Training

Question #1

An administrator is implementing LTO-5 drives in their backup solution. They plan to disable hardware data compression through their backup appliance.

What is the maximum data rate that can be achieved?

  • A . 80 MB/s
  • B . 120 MB/s
  • C . 140 MB/s
  • D . 160 MB/s

Reveal Solution Hide Solution

Correct Answer: C
Question #2

A server is experiencing issues with completing POST. The environment does not have a KVM or “Crash cart” available to view where the system is halting.

Which method can an administrator use to determine the first place to start troubleshooting?

  • A . Run OpenManage Essentials
  • B . Check rear lights on the server chassis
  • C . Run Repository manager
  • D . Check iDRAC Post Code

Reveal Solution Hide Solution

Correct Answer: B
Question #3

What advantage do NVDIMMs have over other server-based memory technologies?

  • A . Operate at lower voltages to save on power costs.
  • B . Lower cost per GB of capacity
  • C . Require less cooling than traditional memory DIMMs
  • D . Can retain contents even after a power loss

Reveal Solution Hide Solution

Correct Answer: D
D

Explanation:

Reference: https://topics-cdn.dell.com/pdf/poweredge-r740_users-guide3_en-us.pdf

Question #4

What is an accurate statement in reference to software RAID?

  • A . Software RAID does not have any data integrity issues
  • B . Software RAID requires a hardware license
  • C . Software RAID is an additional cost
  • D . Software RAID uses CPU resources

Reveal Solution Hide Solution

Correct Answer: D
Question #5

What is a consideration for a hardware administrator who is physically installing multiple servers into a rack?

  • A . Observe load requirements specified in documentation for the switch.
  • B . Avoid unevenly loading the rack and creating a hazard.
  • C . Ensure that the server can connect to Windows updates
  • D . Ensure that the associated UPS can also power the top-of-rack switch.

Reveal Solution Hide Solution

Correct Answer: A
Question #6

Where can a history of change related to hardware components for a managed system be found?

  • A . Windows Event Logs
  • B . Raid Controller Logs
  • C . Lifecycle Logs
  • D . System Event Logs

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://www.dell.com/support/article/pk/en/pkbiz1/sln305828/poweredge-how-to-generate­servers-logs-with-the-idrac-?lang=en

Question #7

What types of data transfer are used by Dell EMC servers to connect mass storage devices?

  • A . USB, Ethernet, SSD, and CSI
  • B . SAS, USB, Ethernet, and SSID
  • C . SSID, CSI, USB, and SAS
  • D . Ethernet, SSID, CSI, and SAS

Reveal Solution Hide Solution

Correct Answer: B
Question #8

Which RAID level is recommended for high speed data access and maximum storage capacity?

  • A . RAID 0
  • B . RAID 1
  • C . RAID 5
  • D . RAID 6

Reveal Solution Hide Solution

Correct Answer: C
Question #9

What is the Dell EMC iSM?

  • A . Agent that expands iDRAC management functionality into the host operating system
  • B . Program that is installed and provides one-to-one systems management functionality
  • C . Systems management console that simplifies monitoring of multiple Dell EMC servers
  • D . Out-of-band management platform on Dell EMC servers

Reveal Solution Hide Solution

Correct Answer: A
A

Explanation:

Reference: https://www.dell.com/support/article/pk/en/pkbsd1/sln310557/dell-emc-idrac-service-module? lang=en

Question #10

Which protocol resolves IP addresses into MAC addresses?

  • A . ARP
  • B . DHCP
  • C . DNS
  • D . STP

Reveal Solution Hide Solution

Correct Answer: A
A

Explanation:

Reference: https://www.globalknowledge.com/blog/2009/08/28/address-resolution-protocol-arp/

Question #11

For which use case is Dell EMC OpenManage Essentials recommended for installation?

  • A . Comprehensive, one-to-one systems management solution for remote or local servers
  • B . Management console for one-to-many monitoring of Dell EMC infrastructure
  • C . Operation of hardware while iDRAC is non-functional
  • D . Management and integration of operating system updates across an entire environment

Reveal Solution Hide Solution

Correct Answer: B
B

Explanation:

Reference: https://www.dell.com/support/home/pk/en/pkbsd1/drivers/driversdetails?driverid=3mrw4

Question #12

What occurs during the Data Wiping process?

  • A . Destroys CDs and DVDs by pulverizing and cross-cut shredding
  • B . Disposes sensitive data using file detection, disk formatting, and file encryption
  • C . Temporarily removes data from a readwrite medium so that it can no longer be read
  • D . Logically connects storage media to a bulk-wiping device

Reveal Solution Hide Solution

Correct Answer: B
B

Explanation:

Reference: https://www.dell.com/support/article/pk/en/pkbsd1/sln300245/using-the-dell-bios-data-wipe­function-for-optiplex-precision-and-latitude-systems-built-after-november-2015?lang=en

Question #13

What should an administrator review, prior to deploying an operating system (OS), to confirm there are no hardware incompatibilities with the desired OS?

  • A . iDRAC SEL
  • B . HCL
  • C . BPA
  • D . LCC Log

Reveal Solution Hide Solution

Correct Answer: A
Question #14

What is the purpose of the DNS role?

  • A . Send out emails from a server to a client
  • B . Translate domain names into IP address
  • C . transfer computer files between a client and a server
  • D . Distribute and update dynamic IP address

Reveal Solution Hide Solution

Correct Answer: B
Question #15

What does well organized documentation help a system administrator improve?

  • A . Cost of running a server
  • B . Visibility of a system during an audit.
  • C . Processor efficiency
  • D . Recovery time in the event of a failure

Reveal Solution Hide Solution

Correct Answer: D
Question #16

Which advanced feature does a Dell EMC energy-smart power supply offer?

  • A . Provides thermal management of the supply
  • B . Reverses airflow to meet data center requirements
  • C . Throttles output to power-heavy components
  • D . Ability to update firmware without the need for downtime

Reveal Solution Hide Solution

Correct Answer: A
Question #17

What is commonly used by a system administrator to prevent electrostatic discharge when working on components inside a Dell EMC PowerEdge server?

  • A . Uninterruptible Power Supply
  • B . Voltage Regulator
  • C . Anti-static wrist strap
  • D . Non anti-static floor mat

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://topics-cdn.dell.com/pdf/poweredge-c6320p_users-guide15_en-us.pdf

Question #18

A system administrator wants to view the results of the Best Practices Analyzer (BPA) for their local server.

Which Windows built-in tool can they use to accomplish this?

  • A . Activity Monitor
  • B . Server Manager-Local Server
  • C . Resource Monitor
  • D . Security Compliance Manager

Reveal Solution Hide Solution

Correct Answer: B
Question #19

What is a key characteristic of a Type 2 hypervisor?

  • A . Runs directly on the host with direct access to the hardware
  • B . Runs directly on the host without direct access to the hardware
  • C . Runs on an operating system installed on the host with direct access to the hardware
  • D . Runs on an operating system installed on the host without direct access to the hardware

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://searchservervirtualization.techtarget.com/definition/hosted-hypervisor-Type-2­hypervisor

Question #20

What distinguishes server CPUs from client CPUs?

  • A . Server CPUs have no overlocking features; client CPUs do have them
  • B . Server CPUs use identical socket types, client CPUs use multiple socket types
  • C . Server CPUs frequently have fewer cores and more processing power than client CPUs
  • D . Servers tend to have fewer CPUs installed than clients

Reveal Solution Hide Solution

Correct Answer: A
A

Explanation:

Reference: https://www.quora.com/How-can-you-describe-the-difference-between-server-CPU-and­desktop-CPU

Question #21

What is the maximum number of iDRAC Virtual Console sessions that can be run simultaneously?

  • A . 5
  • B . 5
  • C . 6
  • D . 7

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://www.dell.com/support/manuals/us/en/04/poweredge-r740xd/idrac_3.00.00.00_ug/ configuring-and-using-virtual-console?guid=guid-1607d2bc-0ed1-4487-84e1-272357a474ae&lang=en-us

Question #22

Which dual-level RAID configuration is combined to configure RAID 10 on a single array?

  • A . RAID 0 RAID 1, mirrored and parity
  • B . RAID 0 RAID 1, mirrored and striped
  • C . RAID 1 RAID 0, parity and striped
  • D . RAID 0 RAID 1, striped and mirrored

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://www.thegeekstuff.com/2010/08/raid-levels-tutorial

Question #23

DRAG DROP

What is the correct sequence of message exchanges between a DHCP server and Client for a connection request?

Reveal Solution Hide Solution

Correct Answer:

Explanation:

Reference: https://www.ionos.com/digitalguide/server/configuration/dhcp-an-overview-of-the-clientserver­protocol/


Question #24

Which open source operating system is designed to handle demanding business applications such as network and system administration, database management, and web services?

  • A . Linux
  • B . AIX
  • C . Windows
  • D . ESXi

Reveal Solution Hide Solution

Correct Answer: A
A

Explanation:

Reference: https://www.webopedia.com/TERM/L/linux_server.html

Question #25

DRAG DROP

Reveal Solution Hide Solution

Correct Answer:


Question #26

An administrator is scheduling a software patch in an enterprise environment.

What is a consideration for the administrator regarding potential impact to users?

  • A . Server Redundancy
  • B . Update file size
  • C . Disruption of workflow
  • D . Network Bandwidth

Reveal Solution Hide Solution

Correct Answer: C
Question #26

An administrator is scheduling a software patch in an enterprise environment.

What is a consideration for the administrator regarding potential impact to users?

  • A . Server Redundancy
  • B . Update file size
  • C . Disruption of workflow
  • D . Network Bandwidth

Reveal Solution Hide Solution

Correct Answer: C
Question #28

254.10.26. The client system is correctly wired.

Which server role should the administrator investigate?

  • A . PROXY
  • B . TCP/IP
  • C . SNMP
  • D . DHCP

Reveal Solution Hide Solution

Correct Answer: D
Question #29

Which initial menu option should be chosen from the iDRAC Virtual Console to access System Setup?

  • A . Lifecycle Controller
  • B . Next Boot
  • C . Normal Boot
  • D . Virtual CD/DVD

Reveal Solution Hide Solution

Correct Answer: A
A

Explanation:

Reference: https://www.dell.com/support/article/pk/en/pkbsd1/sln306877/dell-poweredge-how-to-configure­the-idrac-9-and-the-lifecycle-controller?lang=en

Question #30

What is a benefit of SAS technology?

  • A . Has no moving parts available
  • B . Used for storage back-plane or HDD carrier applications
  • C . Easy to manage cable and cable length
  • D . Has two drives per cable connector

Reveal Solution Hide Solution

Correct Answer: B
B

Explanation:

Reference: http://www.mouser.com/ds/2/18/FCI_bwb_sas-941993.pdf

Question #31

Which solution is recommended for installing a hypervisor in a Dell EMC PowerEdge rack server or in a hyper-converged infrastructure (HCI) host?

  • A . FC HBA
  • B . BOSS
  • C . CPU
  • D . NVDIMM

Reveal Solution Hide Solution

Correct Answer: A
Question #32

What is an accurate statement regarding 40 Gbps Ethernet ports?

  • A . Can be used as a single 40 Gb connector or used as four 10 Gb connections
  • B . Cannot be configured into a stack connection
  • C . Must be segmented into four independent 10 Gb connections
  • D . May only be used as a non-negotiable, single 40 Gb link

Reveal Solution Hide Solution

Correct Answer: C
Question #33

Which Ethernet cable type should be installed if high interference is a concern?

  • A . RJ45
  • B . 802.11n
  • C . STP
  • D . UTP

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://www.makeuseof.com/tag/everything-you-need-to-know-about-ethernet-cables/

Question #34

Why is a mandatory practice to review the service manual prior to replacing or reseating components on a Dell EMC PowerEdge server?

  • A . Service manual gives detailed instructions at which firmware levels the components should run
  • B . Service manual provides vital information on which live wires in the system to avoid, to ensure electric shock does not occur
  • C . Service manual covers crucial cable routing and special part handling instructions
  • D . Service manual describes how to reconfigure the server for optional performance-boosting settings, increasing efficiency

Reveal Solution Hide Solution

Correct Answer: C
Question #35

Based on the exhibit, which device is a Boot Optimized Storage Solution (BOSS) Controller?

  • A . A
  • B . B
  • C . D.
  • D . C

Reveal Solution Hide Solution

Correct Answer: A
A

Explanation:

Reference: https://vinfrastructure.it/2017/09/dell-boot-optimized-storage-solution-boss/

Question #36

What is the maximum bootable storage capacity supported by BIOS mode?

  • A . 512 GB
  • B . 1 TB
  • C . 2 TB
  • D . 4 TB

Reveal Solution Hide Solution

Correct Answer: C
C

Explanation:

Reference: https://www.dell.com/community/PowerEdge-HDD-SCSI-RAID/Maximum-Storage/td­p/4013574

Exit mobile version