Which two firmware packages are included in the Cisco UCS C-Series Rack-Mount UCS-Managed Server Software bundle? (Choose two.)
Which two firmware packages are included in the Cisco UCS C-Series Rack-Mount UCS-Managed Server Software bundle? (Choose two.)A . system B. third-party C. PSU D. CIMC E. BIOSView AnswerAnswer: D, E Explanation: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Firmware-Mgmt/4-0/b_UCSM_GUI_Firmware_Management_Guide_4-0/b_UCSM_GUI_Firmware_Management_Guide_4-0_chapter_0100.html
A network engineer is asked to describe the cloud infrastructure models from the perspective of their operation and access to resources
DRAG DROP A network engineer is asked to describe the cloud infrastructure models from the perspective of their operation and access to resources. Drag and drop the descriptions from the left onto the appropriate. View AnswerAnswer: Explanation: Private Cloud: owned, managed, and operated by a single organization. Community Cloud: Owned,...
Which method does Cisco recommend to configure the SAN boot?
An engineer must implement a Cisco UCS system at a customer site. One of the requirements is to implement SAN boot. The storage system maps the source WWPN to a unique LUN. Which method does Cisco recommend to configure the SAN boot?A . Create a SAN boot policy in which...
Which type of backup is required to restore a Cisco UCS configuration?
Refer to the exhibit. Which type of backup is required to restore a Cisco UCS configuration?A . system configuration B. all configuration C. logical configuration D. full stateView AnswerAnswer: A Explanation: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/cli/config/guide/1-0-2/b_CLI_Config_Guide_1-0-2/CLI_Config_Guide_1-0-2_chapter29.pdf Which configuration command set must be applied to meet these requirements?
An engineer is implementing security on the Cisco MDS 9000 switch
DRAG DROP An engineer is implementing security on the Cisco MDS 9000 switch. Drag drop the descriptions from the left onto the correct security features on the right. View AnswerAnswer: Explanation: Reference: https://www.cisco.com/en/US/docs/switches/datacenter/nexus5500/sw/san_switching/7x/b_5500_SAN_Switching_Config_7x_chapter_010010.html#con_1170967
Which set of commands must be used to meet these requirements?
A Cisco MDS 9000 Series Switch is configured for SAN Analytics and SAN Telemetry Streaming. An engineer must enable analytics for NVMe on interfaces in the range of fc1/1-12. Due to a large amount of traffic generated in the SAN environment, the data must be collected at regular intervals of...
Which set of commands must be used to implement the scenario?
An engineer must configure a Nexus 7000 series switch for HSRP on VLAN 100. When fully functional, the router must be the active master. Which set of commands must be used to implement the scenario? A . Option A B. Option B C. Option C D. Option DView AnswerAnswer: A...
Drag and drop the storage technologies from the left onto the correct descriptions on the right
DRAG DROP Drag and drop the storage technologies from the left onto the correct descriptions on the right. View AnswerAnswer: Explanation: The release of NFSv4 brought a revolution to authentication and security to NFS exports. NFSv4 mandates the implementation of the RPCSEC_GSS kernel module, the Kerberos version 5 GSS-API mechanism,...
Which configuration should be applied to meet the requirement?
A network engineer must configure a power redundancy policy on a Cisco UCS C-Series Rack Server. The power redundancy must support two power sources being used to power the server. Which configuration should be applied to meet the requirement? A . Option A B. Option B C. Option C D....
An engineer deploys a custom Guest Shell rootfs on a Nexus 9000 Series Switch
DRAG DROP An engineer deploys a custom Guest Shell rootfs on a Nexus 9000 Series Switch. Drag and drop the steps from the left into the order required to deploy the solution on the right. Not all options are used. View AnswerAnswer: Explanation: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/93x/progammability/guide/b-cisco-nexus-9000-series-nx-os-programmability-guide-93x/b-cisco-nexus-9000-series-nx-os-programmability-guide-93x_chapter_0100.html