Which element is the main functional component of the architecture that separates the internal fabric and the external network that connects sites when VXLAN EVPN is deployed multisite?

Which element is the main functional component of the architecture that separates the internal fabric and the external network that connects sites when VXLAN EVPN is deployed multisite?A . border leafB . service leafC . border gatewayD . service gatewayView AnswerAnswer: C Explanation: Reference: https://dcloud-cms.cisco.com/demo_news/cisco-dcnm-11-3-for-vxlan-evpn-multi-site-deployments-lab-v1

May 30, 2021 No Comments READ MORE +

Which two solutions must be used to meet these requirements?

An engineer finishes the initial set up of a VXLAN EVPN network. The engineer is asked to plan for external connectivity that supports redundancy and extends multiple virtual routing and forwarding domains. The requirement is to use the same default gateway addressing across all leaf switches that belong to the...

May 29, 2021 No Comments READ MORE +

How is out-of-band management access provided for each VDC?

The management of the Cisco Nexus switches is provided over an isolated put-of-band network. The VDC feature is configured on the Cisco Nexus core switches . How is out-of-band management access provided for each VDC?A . All the VDC have the same out-of-band IP address.B . Each VDC has a...

May 29, 2021 No Comments READ MORE +

What is the result of this policy?

Refer to the exhibit. A Cisco UCS chassis that has two IOMs is discovered. The chassis discovery policy creates a fabric port channel . What is the result of this policy?A . Cisco UCS Manager creates two separate fabric port channels.B . Cisco UCS Manager creates a single fabric port...

May 29, 2021 No Comments READ MORE +

Which two technologies meet this requirement?

An engineer is designing a Multichassis EtherChannel topology in which two switches must appear as a single device to a third downstream switch? Which two technologies meet this requirement? (Choose two.)A . HSRPB . VSSC . vPCD . 802.1qE . FEXView AnswerAnswer: B,C Explanation: Reference: https://www.cisco.com/c/dam/en/us/products/collateral/switches/nexus-7000-series-switches/C07-572835-00_NX-OS_vPC_DG.pdf

May 29, 2021 No Comments READ MORE +

A failure occurs on the network between two BFD and OSPF neighbors

DRAG DROP A failure occurs on the network between two BFD and OSPF neighbors. Drag and drop the protocol actions from the left into the correct order on the right. View AnswerAnswer: Explanation: Reference: https://www.cisco.com/c/en/us/td/docs/ios/12_0s/feature/guide/fs_bfd.html#wp1238898

May 29, 2021 No Comments READ MORE +

Which two statements describe Ethernet switching mode on Cisco UCS 6100 Series Fabric Interconnects? (Choose two.)

Which two statements describe Ethernet switching mode on Cisco UCS 6100 Series Fabric Interconnects? (Choose two.)A . STP runs on the uplink ports of each VLAN, as defined by PVSTP+.B . STP runs on the uplink ports of each VLAN, as defined by MSTD . The STP parameter configuration is...

May 29, 2021 No Comments READ MORE +

What are two reasons to select OTV as the DCI solution to connect multisite topologies? (Choose two.)

What are two reasons to select OTV as the DCI solution to connect multisite topologies? (Choose two.)A . It propagates hosts reachability without support of traffic flooding.B . Layer 3 failures do not propagate beyond the OTV edge device.C . It extends the spanning tree between data centers.D . It...

May 29, 2021 No Comments READ MORE +

What is the disadvantage of asynchronous storage replication as compared to synchronous storage replication in a disaster recovery design?

What is the disadvantage of asynchronous storage replication as compared to synchronous storage replication in a disaster recovery design?A . reduction in application performanceB . distance limitationsC . specific backup requirementsD . potential data lossView AnswerAnswer: D Explanation: Reference: https://www.evidian.com/products/high-availability-software-for-application-clustering/synchronous-replication-vs-asynchronous-replication/

May 28, 2021 No Comments READ MORE +

Which mode must be enabled on a Cisco UCS Fabric Interconnect to connect directly to a storage array?

Which mode must be enabled on a Cisco UCS Fabric Interconnect to connect directly to a storage array?A . NPIV modeB . FC end-host modeC . NPV modeD . FC switching modeView AnswerAnswer: D Explanation: Section: Storage Network Design Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Storage-Mgmt/3-1/b_UCSM_GUI_Storage_Management_Guide_3_1/b_UCSM_GUI_Storage_Management_Guide_3_1_chapter_01110.html

May 28, 2021 No Comments READ MORE +