Which mode must be enabled on a Cisco UCS Fabric Interconnect to connect directly to a storage array?

Which mode must be enabled on a Cisco UCS Fabric Interconnect to connect directly to a storage array?A . NPIV modeB . FC end-host modeC . NPV modeD . FC switching modeView AnswerAnswer: D Explanation: Section: Storage Network Design Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Storage-Mgmt/3-1/b_UCSM_GUI_Storage_Management_Guide_3_1/b_UCSM_GUI_Storage_Management_Guide_3_1_chapter_01110.html

October 27, 2021 No Comments READ MORE +

Which addressing scheme was used in the environment?

An engineer is expanding an existing ISCSI environment and must choose an addressing scheme. When checking one of the devices, the engineer discovers this target device naming used {prefix}. 2019-01.com.acme.123:00. ftd0cb21.bcb389458389 Which addressing scheme was used in the environment?A . Extended Unique identifierB . Fibre Channel IDC . ISCSI Qualified...

June 11, 2021 No Comments READ MORE +

Drag and drop the feature descriptions from the left onto the correct UCS Fabric Interconnect modes on the right

DRAG DROP Drag and drop the feature descriptions from the left onto the correct UCS Fabric Interconnect modes on the right. View AnswerAnswer:

June 11, 2021 1 Comment READ MORE +

Which DCI technology meets these requirements?

A customer wants to deploy a Layer 2 extension over a transport infrastructure for multiple data centers. The data center technology should support a localized Layer 3 gateway, a separate flooding domain, and STP isolation per data center . Which DCI technology meets these requirements?A . PseudowireB . VXLAN EVPNC...

June 10, 2021 No Comments READ MORE +

What is a design consideration when implementing FSPF?

What is a design consideration when implementing FSPF?A . Routes are based on the domain IC . Routes are based on the distance vector protocol.D . FSPF runs only on F Ports.E . FSPF runs on a per-chassis basis.View AnswerAnswer: A Explanation: Reference: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/5_0/configuration/guides/fabric/nxos/cli_fabric/fspf.html

June 10, 2021 No Comments READ MORE +

What must be the default gateway of the servers in EPG Web?

Refer to the exhibit. What must be the default gateway of the servers in EPG Web?A . subnet address of BD1B . subnet address of L3OutC . subnet address of BD2D . NAT applianceView AnswerAnswer: A

June 10, 2021 1 Comment READ MORE +

Which solution meets these requirements?

An engineer must interconnect two geographically separated data centers. The service provide offers a Layer 2 metro Ethernet link. The strict security policy requires that the information that is shared between two sites must be sent encrypted. The application deployed between sites requires a line-rate throughput regardless of the packet...

June 10, 2021 No Comments READ MORE +

Which authentication software natively runs within the CLI of Cisco NX-OS devices?

Which authentication software natively runs within the CLI of Cisco NX-OS devices?A . PythonB . AnsibleC . PuppetD . ChefView AnswerAnswer: A

June 10, 2021 1 Comment READ MORE +

Which type fields can an engineer use to identify an iSCSI participant? (Choose two.)

Which type fields can an engineer use to identify an iSCSI participant? (Choose two.)A . typeB . preshared keyC . port numberD . identifying tagE . hostnameView AnswerAnswer: C,E Explanation: Reference: https://en.wikipedia.org/wiki/ISCSI

June 9, 2021 No Comments READ MORE +

Which Ethernet to Cisco Fabric Interconnect connectivity configuration is supported when FCoE is implemented?

Which Ethernet to Cisco Fabric Interconnect connectivity configuration is supported when FCoE is implemented?A . VSS that has unified uplinksB . Ethernet and unified ports on the same port channelC . vPC that has unified uplinksD . cross-connections with pinningView AnswerAnswer: D

June 8, 2021 No Comments READ MORE +