Cisco 300-180 Troubleshooting Cisco Data Center Infrastructure Online Training
Cisco 300-180 Online Training
The questions for 300-180 were last updated at Oct 24,2025.
- Exam Code: 300-180
- Exam Name: Troubleshooting Cisco Data Center Infrastructure
- Certification Provider: Cisco
- Latest update: Oct 24,2025
Which two types of ports does end host mode switching have? (Choose two.)
- A . VSS
- B . border
- C . router
- D . server
- E . STP
- F . client
In a Cisco UCS environment, what are the three power types in a power policy? (Choose three.)
- A . backup
- B . grid
- C . redund
- D . n-plus-1
- E . non-redund
- F . plus-1
When a service profile is disassociated from a server, what happens to the identity and connectivity information for the server?
- A . It is cleared and set to the default that was setup initially by the first configuration.
- B . It is maintained and can be reused.
- C . It is reset to factory defaults.
- D . It uses master service profile parameters.
- E . It takes parameters of other servers in the service profile.
At any given time, each server can be associated with how many service profiles?
- A . 1
- B . 2
- C . 5
- D . 10
- E . unlimited
Refer to the exhibit.

Using RBAC for security in a Cisco UCS environment, what is seen in the exhibit?
- A . custom role
- B . default role
- C . LDAP group map
- D . external service profile
Refer to the exhibit.

Which of these is an extension of the virtual machine abstraction that is applied to physical servers?
- A . service profile
- B . compute profile
- C . organization profile
- D . locale profile
- E . role profile
In new Cisco UCS release 2.0 installations, what are the default VLAN IDs?
- A . Ethernet VLAN default ID is 4048, FCOE default VLAN ID 4048
- B . Ethernet VLAN default ID is 1, FCOE default VLAN ID is 3968
- C . Ethernet VLAN default ID is 1, FCOE default VLAN ID is 2
- D . Ethernet VLAN default ID is 2, FCOE default VLAN ID is 4047
- E . Ethernet VLAN default ID is 1, FCOE default VLAN ID is 4048
If a server is not associated with a service profile, the activated firmware remains pending.
Which two steps should you take? (Choose two.)
- A . Manually reboot the server.
- B . Reset the server to a new profile.
- C . Reset the unassociated server to activate the firmware.
- D . Reinitialize the firmware process with Cisco UCS Manager.
- E . Download the firmware and start over.
- F . Shut down gracefully and start over.
After migrating a server that is configured with dynamic vNICs, Cisco UCS Manager assigns new dynamic vNICs to the server.
If you had been monitoring traffic on an original dynamic vNIC, what must you do when the server comes back up?"
- A . Reassign the dynamic vNIC back to the old configuration.
- B . Nothing; Cisco UCS Manager will take over.
- C . Reassign the service profile back to the master one.
- D . Remove and reconfigure the dynamic vNIC.
- E . Reassign the monitoring source.
Which two Cisco Nexus 2000-Series Fabric Extenders support connections to both Cisco Nexus 5000 Series Switches and Cisco Nexus 7000 Series Switches? (Choose two.)
- A . Cisco Nexus 2248TP
- B . Cisco Nexus 2248TP-E
- C . Cisco Nexus 2232PP
- D . Cisco Nexus 2232TM