Looking at the Equipment > Chassis > Servers > Server X view from the Cisco UCS Manager GUI, which tab would you select to identify the fabric interconnect uplink associated with a given virtual circuit?
- A . Paths
- B . vNIC Paths
- C . Virtual Circuit Paths
- D . VIF Paths
While attempting to boot a Cisco UCS server from SAN, you are unable to see the LUN.
Which of these are causing the problem? (Choose three.)
- A . VHBA template
- B . RAID policy
- C . zoning
- D . LUN ID
- E . vACLs
- F . disjoint fabrics
A Cisco UCS chassis has two ports on I/O Module 1 connected to Fabric Interconnect A, and two ports on I/O Module 2 connected to Fabric Interconnect B . The I/O modules are connected to ports 1 and 2 on their respective fabric interconnects, and end host mode is configured.
After a link failure occurs on port 1 of I/O Module 1, what happens to the traffic that was pinned to that link?
- A . The traffic fails until the link issue is resolved.
- B . The traffic is repinned to I/O Module 2 link 1, which is connected to Fabric Interconnect B.
- C . The traffic is repinned to the remaining link between I/O Module 1 and Fabric Interconnect A.
- D . The traffic is repinned automatically to Fabric Interconnect B.
During a password recovery of a Cisco UCS system in a cluster configuration, what happens to blade traffic?
- A . There is no interruption to traffic, as the fabrics go down one at a time.
- B . Traffic stops flowing until the process is complete.
- C . There is no interruption to traffic because both fabrics stay up the whole time.
- D . Traffic will continue to flow, but at a limited rate until the process is complete.
For a KVM session to be successful, which two of these need to be done? (Choose two.)
- A . The Cisco IMC IP address needs to be assigned on the Admin tab.
- B . The Cisco IMC IP address needs to be in the same subnet as the management IP.
- C . The Cisco IMC needs to be upgraded to the same version as the UCS Manager.
- D . The server needs to be fully discovered.
As a Cisco UCS administrator, you have a large deployment of C-Series servers. You decide to integrate these into a Cisco UCS Manager environment to simplify management.
Which two of these will you need to purchase? (Choose two.)
- A . two fabric interconnects
- B . a dedicated Cisco IMC
- C . two fabric extenders
- D . two I/O modules
Which three Cisco UCS server components can be upgraded via a host firmware package? (Choose three.)
- A . BIOS
- B . Cisco UCS Manager
- C . I/O module
- D . Cisco IMC
- E . fabric interconnect
- F . adapter
- G . board controller
Which three methods can be used to upgrade the Cisco IMC? (Choose three.)
- A . host firmware package
- B . blade firmware package
- C . controller firmware package
- D . management firmware package
- E . directly on the blade, under the Installed Firmware tab
- F . directly on the blade, under the Blade Firmware tab
- G . directly on the blade, under Inventory > CIMC
Which of these is a supported Cisco C-Series integration topology?
A)

B)

C)

D)

- A . Exhibit A
- B . Exhibit B
- C . Exhibit C
- D . Exhibit D
Which command sequence in the Cisco UCS C-Series rack server CLI sends tech support data to a TFTP server?
- A . ucs-c250 / # scope cimc
ucs-c250 /cimc # scope tech-support
ucs-c250 /cimc/tech-support # set path default.tar.gz
ucs-c250 /cimc/tech-support *# set tftp-ip 192.168.70.45
ucs-c250 /cimc/tech-support *# commit - B . ucs-c250 / # scope system
ucs-c250 /system # scope tech-support
ucs-c250 /system/tech-support # set path default.tar.gz
ucs-c250 /system/tech-support *# set tftp-ip 192.168.70.45
ucs-c250 /system/tech-support *# commit - C . ucs-c250 / # scope support
ucs-c250 /support # scope tech-support
ucs-c250 /support/tech-support # set path default.tar.gz
ucs-c250 /support/tech-support *# set tftp-ip 192.168.70.45
ucs-c250 /support/tech-support *# commit - D . ucs-c250 / # scope fault
ucs-c250 /fault # scope tech-support
ucs-c250 /fault/tech-support # set path default.tar.gz
ucs-c250 /fault/tech-support *# set tftp-ip 192.168.70.45
ucs-c250 /fault/tech-support *# commit