Based on the output, which action resolves this issue?

Refer to the exhibit.

An engineer is configuring an EtherChannel between Switch1 and Switch2 and notices the console message on switch2.

Based on the output, which action resolves this issue?
A . Configure less member ports on Switch2.
B. Configure the same port channel interface number on both switches
C. Configure the same EtherChannel protocol on both switches
D. Configure more member ports on Switch1.

Answer: C

Explanation:

In this case, we are using your EtherChannel without a negotiation protocol on Switch2. As a result, if the opposite switch is not also configured for EtherChannel operation on the respective ports, there is a danger of a switching loop. The EtherChannel Misconfiguration Guard tries to prevent that loop from occuring by disabling all the ports bundled in the

EtherChannel.